![background image](http://html1.mh-extra.com/html/dps-telecom/netguardian-16s/netguardian-16s_user-manual_2525745058.webp)
52
System Alarm Descriptions
15.2
Point
System Alarm
Description
9
Modem not Responding
Modem not responding to initialization string
10
No Dialtone
Dial tone not detected during dial-out attempt
11
Pager Que Overflow
Over 250 unsent events in pager queue
12
Pager Notify Failed
Attempted pager notification unsuccessful
13
Callout Que Overflow
Over 8 unsent calls in Voice Call Out queue
14
Callout Notify Failed
Attempted Voice Call Out unsuccessful
15
Exp. Module Callout
Alarm collected from Entry Control Unit (ECU)
33
Unit Reset
Toggles whenever unit reboots
34
Lost Provisioning
Unit using default configuration settings. NVRAM
may be damaged
35
Intra-communication Fail
Communications failure between the
NetGuardian-16S’s two circuit boards
36
Private LAN not Active
Ethernet link not detected on Private port
37
Public LAN not Active
Ethernet link not detected on Public port
38
Duplicate Private IPA
Unit detects another node with same IP address as
the Private port
39
Duplicate Public IPA
Unit detects another node with same IP address as
the Public port
40
DCP Poller Inactive
Unit has not received poll from T/Mon for longer
than DCP Timer period set by system administrator
41
DCP Event Que Full
More than 500 uncollected events in DCP event
queue
42
SNMP Trap not Sent
SNMP trap address is not defined and an SNMP
Trap event occurred
43
Network Time Server
Communication to network time server failure
44
BSU Standalone Mode
Communication with CopperController failure and
BSU enters Standalone Mode.
45
Serial Rcv Overflow
UART hardware overflowed during receive
46
Serial Rcv Que Full
Alarm set when any data port is filled with more
than 16K of information
47
Timed Tick
Toggles state at constant rate set by Timed Tick
period configured by system administrator
48
Channel Port Timeout
Channel port has not forwarded any traffic for
longer than Channel Port Timeout period set by
system administrator
49
Craft Port Timeout
Craft Timeout Timer has not been reset in the
period set by system administrator
50
NGDdx Expansion Fail
Communication to NetGuardian-16S Expansion
unit(s) failure
Table 15.5.A.
System alarm descriptions