2.2.2 Setting the Internal Address & Baud Rate (v1.0E or newer)
Each unit must have a separate internal address. The address is stored internally and only needs to be set once
prior to use.
To set the internal address:
1). Enter Set Address mode by simultaneously holding down the + and – buttons.
2.) To set address press select.
3). Use the +/- buttons to choose address.
3). Press SEL to accept the displayed address. An asterisk (*) will appear next to the address you have accepted.
e.g.: GLD Addr: 2*
4). Press MOD to exit Set Address mode.
2.2.2.1 Setting Baud Rate
To set the baud rate:
1). Enter Set baud rate mode by simultaneously holding down the + and – buttons.
2.) Press +, you will see "GLD baud".
3). Press SEL, then use the +/- buttons to adjust baud rate.
3). Press SEL to set.
4). Press MOD to exit.
2.2.3 LED Indications
The Link LED indicates communication with the host. A red flash shows receive activity, while a green flash shows
transmit activity.
A slow red blink represents a communication link idle for more than 2 minutes, which is considered a
communication failure. The LCD will show “Link Down.”
2.2.4 Audible Notification
The host may activate the GLD speaker as certain conditions occur. Press the MOD/ACO button to locally
terminate the sound.
2.2.5 LCD Operation
Refer to the host’s manual for specific operation details.
* If using only 1 GLD unit, the address must be set to 1.