TCX-OS command list
AWX can be programmed using 3 letter commands. The commands are the
same, via SMS or via PC interface.
You can use lower case or upper case letters, or a mixture of the 2.
For example: PWD=pwd=Pwd.
Do not put spaces or other characters in the command string or among
commands.
Remember that EVERY command must start with a octothorpe (#)
This is a list of the commands most used:
#APN:
Defines the Access Point Name for GPRS
#END
: Exit from programming menu (if using a PC)
#GTM:
ask weather data via SMS
#INI:
Initialize all parameters
#LGG:
define GPRS interval for sending data
#MHD
: Program the NAME of the station (max 10 characters)
#NOA
: Do not send acknowledgement SMS
#PWD
: Password (followed by 6 digits password)
#RTC
: Program real time clock date and time
#SCT
: Sync real time clock with incoming message timestamp
#SLP
: Enable/Disable (1/0) Sleep mode to save power
#SMC
: SMS counters and 24h maximum
#UDM:
Define the control system used for UPD packets (echo etc.)
#UIP:
Define IP address and port