background image

8

Returning for Service

Returning for Service

Before returning the instrument for service…

1.Install new batteries in the proper alignment as shown within

battery compartment.

2.Examine the surface temperature probe tip for dirt or damage.

3.Ensure the holes in the white humidity/air temperature sensor

are clear. 

4.Perform a 

Reset

(Page 4) 

If you must return the instrument for service, please fill out and
include the service form located at www.defelsko.com/support
with the instrument.

To ensure optimal performance of your 

PosiTector

DPM

,

do not obstruct the airflow near the air temperature and

humidity sensors. Keep fingers away from the sensor, as body
heat can cause incorrect readings. Allow time for the instrument to
acclimate and for the readings to stabilize when moving the
instrument between different environments. 

When using the surface temperature probe, do not use excessive
downward force, and do not drag it sideways. When the instrument
is not in use, place the rubber cap over the surface temperature
sensor to prevent damage.

CAUTION:

Updates

Determines if a software update is available for your instrument
(must be connected to an internet connected PC with 

PosiTector

Desktop Manager

). See: www.defelsko.com/update

Allows the 

PosiTector

to communicate wirelessly with the

PosiTector Desktop Manager (PDM)

or with the optional Bluetooth

wireless printer.

Bluetooth

(Advanced models only)

Summary of Contents for PosiTector

Page 1: ...PosiTector DPM Quick Guide v 3 1 Dew Point Meter...

Page 2: ...sured Ts Surface Temperature measured Td Dew Point calculated Ts Td Surface minus Dew Point Temperature calculated Tw Wet Bulb Temperature calculated Advanced Models Only The PosiTector DPM powers up...

Page 3: ...Bluetooth OFF Trend Chart None Perform a more thorough Hard Reset by powering down the instrument waiting several seconds then simultaneously holding both the center and buttons until the Reset symbol...

Page 4: ...uld be greater than 1 C 2 F This menu item only appears when all memory functions are turned off Wet Bulb readings cannot be stored in memory NOTE Advanced models only Displays a real time graph of th...

Page 5: ...r dimming Advanced only Memory Management Memory Management Memory The PosiTector DPM can record datasets in memory for printing to the optional Bluetooth wireless printer transferring to a computer o...

Page 6: ...the instrument will wake up take a reading sync to PosiTector net if configured and power down The instrument can record approximately 8 000 datasets while in this mode using fresh alkaline batteries...

Page 7: ...connected USB or Bluetooth to an internet connected PC running PosiTector Desktop Manager PDM Sync Now Connect Connect Menu Connect Menu The PosiTector uses a USB mass storage device class which provi...

Page 8: ...umidity sensors Keep fingers away from the sensor as body heat can cause incorrect readings Allow time for the instrument to acclimate and for the readings to stabilize when moving the instrument betw...

Page 9: ...1 F Air Temperature 40 to 80 C 40 to 175 F 0 5 C 1 F 0 1 C 0 1 F Humidity 0 to 100 3 0 1 Operating Range 40 C to 80 C 40 F to 175 F www defelsko com DeFelsko Corporation USA 2011 All Rights Reserved T...