STEREO
ZONE
CABLE REF. W-2
MINIMUM SECTION
2X0.50 MM
Speaker
Ref. SP 5
STEREO
ZONE
CABLE REF. W-2
MINIMUM SECTION
2X0.50 MM
Speaker
Ref. SP 5
WIRING DIAGRAM FOR S 400 BT CONTROL
MODULE AND UC 400 S CENTRAL UNIT
S o u n d & H o m e
A u t o m a t i o n
CONTROL
MODULE WITH
BLUETOOTH
S 400 BT
Technical characteristics
Nr. of channels...................................4 mono channel
Amplifier..............................................1.5+1.5W stereo
Bluetooth............................................A2DP transmission protocol
Minimum load impedance................8 ohms
Power supply......................................12Vcc/330mA
Stand-by power consumption........25mA
Operational power consumption..69mA
Connectors.........................................Strip terminals
Dimensions.........................................44 x 44 x 36mm depth
S 400
VOLUME.
AUXILIARY AUDIO INPUT
ON/OFF KEY
ALARM CLOCK
AND PARENT FUNCTION
MENU KEY
LCD DISPLAY
SELECTOR
BLUETOOTH
CHANNEL AND AUX. IN
RED 230 Vca.
2x0,75 mm.
0
5
8
9
-
+
+
-
ANT
C1L
C1R
R+ R- L- L+
C2L
C2R
C3L
C3R
C4L
C4R
S 400 BT
UC 400 S
0
5
-
+
+
-
ANT
R+ R- L- L+
S 400 BT
0 5 8 9
0 5 8 9
C1 C2 C3 C4
C1 C2 C3 C4
M
M
M
www.doyson.com
NOTE.-
The
UC 400 S
supports a máximum of 10 sound control modules and a maximum distance of 100 mts.of cable to the last
element to be controlled. For higher installations, power supply units or a more powerful central unit would be required.
HOW TO PROGRAM THE SYSTEM:
Once all the system units are already installed, a zone number must be assigned to each control module as follows:
1st.- Keep the keys <> pressed during 4 seconds. The number “1” will be shown on the displays of ever y control module.
2nd.- Choose the control module you want to be the “zone 1” and press the On/Off key. The number “1” will be memorized as a zone number in
that control module.
3rd.- Now the rest of control modules will show the number “2” in their displays. Choose again which control module you want to be the “zone 2”
and press the On/Off key of that module.
4th- Repeat the process as many times as control modules/zones are in the installation.
5th- Once the zone assignment is finished, keep the control module on/off key pressed during 4 secondsin order to leave the “assingnment zone mode”.
CABLE REF. W-14
MINIMUM SECTION
2X1MM
12X0,25 MM
0
5
8
9
C1
C2
C3
C4
GROUND - Vcc
POWER SUPPLY 12 +Vcc
COMMUNICATIONS
COMMUNICATIONS
CHANNEL 1
CHANNEL 2
CHANNEL 3
CHANNEL 4
=
=
=
=
=
=
=
=
System with power supply unit
System with central unit
For AUXILIARY CONNECTION of audio, TV, PC, etc. please
use 0 (ground) and C1
ANTENNA CONNECTION:
Conductor wire of 80 cm. In zones of
bad reception, connection to outdoor antenna it is highly recommended.
FA 12 BI
Power supply
unit