A13
AUTOMATIC STEAM OPTION
INTERVALS TIMES SETTING (GREEN)
INJECTION TIMES SETTING (RED)
INTERVALS MULTIPLICATOR SETTING
STEAM INJECTION MULTIPLICATOR SETTING
SCALE ADJUSTMENT
By pushing the GREEN button, the button will light up and the automatic system injection will
start. The injection will be done as per the pre-adjustment time on the automatic steam timer. The
standard steam timer (white light) will light up during the steam injection. Push the RED button
to stop the automatic steam injection and then, the GREEN button will turn off.
Timer adjustments
EXAMPLE : For 5 seconds of steam injection every 10 minutes : Set the interval multiplicator
screw
(OFF)
at MIN and the GREEN needle at 10. Set the injection multiplicator screw
(ON)
at
SEC and the RED needle at 5.
EXAMPLE : For 2 seconds of steam injection every 25 seconds : Set the interval multiplicator
screw
(OFF)
at SEC and the GREEN needle at 25. Set the injection multiplicator screw
(ON)
at
SEC and the RED needle at 2.
Summary of Contents for JA6
Page 21: ...SECTION B DIMENSIONS ...
Page 24: ...B3 48 1 4 JAOP6 JAOP6 ...
Page 25: ...B4 ENTRÉE D EAU Ø1 4 WATER INLET Ø1 4 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET JAOP6 JAOP6 ...
Page 27: ...B6 48 1 4 37 7 8 JA6 JA6 ...
Page 28: ...B7 ENTRÉE D EAU Ø1 4 WATER INLET Ø1 4 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET JA6 JA6 ...
Page 29: ...SECTION E COMPONENT PARTS ...
Page 30: ...E1 BAKING TIMER THERMOSTAT 1 2 4 6 7 8 12 14 15 16 17 JAOP6 JAOP6 ...
Page 32: ...E3 1 2 5 6 9 11 12 13 14 5 AMPS JAOP6W JAOP6 WATLOW ...
Page 38: ...E9 4 5 1 2 3 JAOP6 JAOP6 ...
Page 40: ...SECTION F CONTROL PANELS ...
Page 49: ...SECTION G ELECTRIC SCHEMATICS ...