Dovre 525CB Installation Instructions And Operating Manual Download Page 12

09-20008-009

1

3

2

1. Open the stove door.

2. Use the scraper (2) to open the ash removal port

(1) by opening the bottom of the fire compartment.

3. Scrape the excess ash through the de-ashing

cover into the ash pan (3) below it.

4. Close the ash removal port.

5. Using the glove supplied, remove the ash pan and

empty it.

6. Replace the ash pan and close the stove door.

Fog and mist

Fog and mist hinder the flow of flue gases through the
flue. Smoke can blow back and cause a stench. If it is
not strictly necessary, it is better not to use the stove
in foggy and misty weather.

Solving problems

Refer to the appendix "Diagnostic diagram" to resolve
any problems in using the stove.

Maintenance

Follow the maintenance instructions in this chapter to
keep the stove in good condition.

Chimney

In many countries, you are required by law to have
your chimney checked and maintained.

At the beginning of the heating season: have the
chimney swept by an expert.

During the heating season and after the chimney
has not been used for a long time: have the
chimney checked for soot deposits.

After the heating season: seal off the chimney with
a ball of paper.

Cleaning and other regular
maintenance activities

Do not clean the stove when it is still warm.

Clean the exterior of the stove with a dry lint-free
cloth.

You can clean the stove interior thoroughly at the end
of the heating season:

If necessary, first remove the fire-resistant inner
plates. See the chapter "Installation" for
instructions on removing and installing the inner
plates.

If necessary, clean the air supply ducts.

Remove the baffle plate at the top of the appliance
and clean it.

Checking fire-resistant inner plates

The fire-resistant inner plates are consumables and
subject to wear . Check the fire-resistant inner plates
frequently and replace them when necessary.

See the chapter "Installation" for instructions on
removing and installing the inner plates.

The insulating vermiculite or chamotte inner
plates may develop hairline cracks, but this
does not affect their performance adversely.

Cast-iron inner plates last a long time if you
remove frequently the ash that can accumulate
behind them. If accumulated ash behind the
cast-iron plate is not removed, the plate will no

12

Subject to change because of technical improvements

Summary of Contents for 525CB

Page 1: ...HOUTKACHEL INSTALLATION INSTRUCTIONS AND OPERATING MANUAL WOOD STOVE INSTALLATION ET MODE D EMPLOI POELE A BOIS EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG HOLZ FEUERST TTE INSTRUCCIONES DE INSTALACI N Y...

Page 2: ...nd connecting 8 Use 9 First use 9 Fuel 9 Lighting 9 Burning wood 10 Controlling combustion air 11 Extinguishing the fire 11 Removing ashes 11 Fog and mist 12 Solving problems 12 Maintenance 12 Chimney...

Page 3: ...cannot be held liable for any problems or damage resulting from incorrect installation Observe the following safety regulations when installing and using the appliance In this manual you can read how...

Page 4: ...ance is installed If ventilation is insufficient combustion will be incomplete resulting in toxic gases being produced and spread through the room See the chapter Installation requirements for more in...

Page 5: ...on the stove needs air oxygen This air is supplied via adjustable air inlets from the area in which the stove is installed The combustion will be incomplete in case of insufficient ventilation which r...

Page 6: ...imary air slide Door lock The appliance is supplied with the latch button installed As the latch button becomes warm during use a glove has been supplied which you may use to protect your hand Install...

Page 7: ...rnal sections 1 bottom of the fire compartment 2 ash removal port 3 back inner plate on the left and right 4 inner plate on the left and right side 5 baffle plate 6 fire basket 7 ashtray Connecting to...

Page 8: ...If the appliance is installed in a room without sufficient ventilation you can install the connecting kit on the appliance for the supply of outside air The air supply tube is 100 mm in diameter If us...

Page 9: ...burns slowly with calm flames Softwood contains more resins burns faster and sparks more Use seasoned wood that contains no more than 20 moisture The wood should have been seasoned for at least 2 yea...

Page 10: ...enly across the bottom of the stove base 3 Stack a few logs on the charcoal Open stacking If the logs are stacked openly the wood will burn quickly as the oxygen can reach each log easily If you want...

Page 11: ...Control the air supply with the secondary air inlet The secondary air inlet not only supplies air to the fire but to the glass as well so that it does not quickly become dirty Open the primary air in...

Page 12: ...checked for soot deposits After the heating season seal off the chimney with a ball of paper Cleaning and other regular maintenance activities Do not clean the stove when it is still warm Clean the e...

Page 13: ...y self lubricating you will still need to lubricate moving parts frequently Lubricate the moving parts such as guide systems hinge pins latches and air slides with heat resistant grease that is availa...

Page 14: ...Flue gas temperature measured in the measurement section 297 C Temperature measured downstream from the flue spigot 353 C Minimum draught 12 Pa CO emission 13 O2 0 09 NOx emission 13 O2 107 mg Nm CnHm...

Page 15: ...Appendix 2 Measurements 525CB 09 00267 000 750 215 490 525 320 415 150 100 295 625 150 475 180 Subject to change because of technical improvements 15...

Page 16: ...ible material Incombustible material thickness 100 mm Please note To guarantee the flow of combustion air when no outside air connection is provided the distance from the outside air connection collar...

Page 17: ...reproof protective plate A B B 09 20002 004 Minimal dimensions of fireproof protective plate A mm B mm Din 18891 500 300 Germany 500 300 Finland 400 100 Norway 300 100 Subject to change because of tec...

Page 18: ...osit hermetically tight no chinks Chimney stack incorrect Sufficiently high above the roof no obstacles in the vicinity Air inlets set incorrectly Open the air inlets completely Stove connected to the...

Page 19: ...glass 13 Cleaning appliance 12 Combustible material distance from 16 Connection measurements 15 Connection collar for connection to chimney 8 Connection to chimney at top 8 top 8 Connection to supply...

Page 20: ...g 13 Measurements 15 Mist do not burn wood 12 N Nominal output 12 14 O Open ash pan 12 ash removal port 12 door 6 Outside air intake connection to 9 P Paint finish 9 Particulate emission 14 Parts remo...

Page 21: ...5 Vermiculite inner plates 7 W Walls fire safety 5 Warning chimney fire 4 9 11 combustible materials 4 fireproof inner plates 9 glass broken or cracked 4 13 hot surface 4 regulations 4 stove window cl...