rear or the upper side. See the paragraphs "Con-
necting on the side or to the rear" and "Connecting to
the upper side". It is also possible to make a con-
nection via the attachment 5T that can be ordered sep-
arately; see the paragraph "Connecting via the
attachment 5T".
A special connection collar is required to connect
to the upper side of the appliance. This connection
collar (along with a cover) can be ordered sep-
arately. The order number is 03.15317.020.
The appliance is not supplied with a flue gas open-
ing.
Sealant and materials supplied.
Connecting to the side or the rear
First of all, choose between the side or the rear to con-
nect the appliance to the chimney. Make the flue gas
opening on the side that you have chosen and then fit
the connection collar supplied with the appliance.
For Germany, the appliance is supplied with a
connection collar with a diameter of 130 mm.
Make the flue gas opening in the appliance by remov-
ing the connection cover. Use the equipment: the ten-
sion piece, the washer, the nut and bolt; see following
figure.
1. In the centre of the connection cover, drill a hole
with a diameter of 10 mm.
2. Place the tension piece and the bolt on the inner
side of the connection cover.
3. Slide the washer over the bolt and tighten the nut
onto the bolt.
On enamelled appliances, place a piece of card-
board measuring a minimum of 20 cm by 20cm
between the washer and the appliance to pro-
tect against chipping of the enamel.
4. Tighten the nut by hand. Use a small amount of
grease to make it easier to turn the nut.
5. Using a ring spanner, tighten the nut so that the
connection cover breaks out.
6. Once made, a flue gas opening can be closed off
again with the supplied shut-off cover (A). Use the
mounting plate (C) and M6x25 bolt (D) to fit the
cover to the appliance (B); see the following figure.
7. Fit the connection collar (C) to the flue gas open-
ing (D) using the two brackets supplied (E) and the
attachment materials (A) and (B); see the figure
below.
10
Subject to change because of technical improvements