material.
The rule of thumb for a single-walled tube is a
distance of 3x the diameter. If a lining shell is
fitted around the tube, a distance of 1x the
diameter is permissible.
Carpets and rugs must be at least 80 cm away
from the fire.
Use a fireproof floor plate to protect a
flammable floor from any ash which may fall in
front of the stove. The protective plate must
comply with national standards.
For the dimensions of the fireproof protective
plate: see the appendix "Distance from
combustible material".
For further requirements in connection with fire
safety: see the appendix "Distance from
combustible material".
Product description
1. Top plate
2. Latch button
3. Bottom of the fire compartment
4. Door
5. Secondary air slide
6. Leg
7. Primary air slide
Features of the appliance
The appliance is an entirely cast-iron design with
modern combustion technology.
The airwash-system ensures prolonged clean
glass and so for an optimal view at the fire.
The appliance is supplied with the latch button
installed. As the latch button becomes warm during
use, a glove has been supplied which you may use
to protect your hand.
The appliance is suitable for connection to outside
air supply. The appliance comes standard with a
connection kit necessary for this.
The appliance can be connected to the chimney at
the rear or at the top.
Installation
General preparation
Please check the appliance immediately after
delivery for damage caused during transport or any
other damage or defects. The appliance is attached
to the pallet with screws at the bottom.
If you detect damage caused during transport
or any other damage or defects, do not use the
appliance and notify the supplier.
Remove the removable parts from the appliance
before you start installing the appliance.
It is easier to move the appliance and to avoid
damage if the removable parts have been
removed.
Note the location of the removable parts, so
that you can re-position the parts in the correct
place later on.
6