![Dover Wilden Original A8 Engineering, Operation & Maintenance Download Page 12](http://html1.mh-extra.com/html/dover/wilden-original-a8/wilden-original-a8_engineering-operation-and-maintenance_2525073012.webp)
10
WILDEN PUMP & ENGINEERING, LLC
WIL-10270-E-02
Height .................................. 668 mm (26.3")
Width ................................... 610 mm (24.0")
Depth .................................. 345 mm (13.6")
Est. Ship Weight ..........Aluminum 33 kg (72 lbs)
Cast Iron 52 kg (114 lbs)
316 Stainless Steel 48 kg (106 lbs)
Air Inlet ....................................19 mm (3/4")
Inlet ............................................ 51 mm (2")
Outlet ......................................... 51 mm (2")
Suction Lift ........................... 3.4 m Dry (11')
9.5 m Wet (31')
Displacement/Stroke ....... 1.66 l (0.44 gal.)
1
Max. Flow Rate ............... 568 lpm (150 gpm)
Max. Size Solids ...................19.0 mm (1/4")
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example:
To pump 322 lpm (85 gpm) against
a discharge pressure head of 2.1 bar (30
psig) requires 4.1 bar (60 psig) and 110.5
Nm
3
/h (65 scfm) air consumption. (See dot
on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
[LPM]
Water Discharge Flow Rates
Height .................................. 668 mm (26.3")
Width ................................... 610 mm (24.0")
Depth .................................. 345 mm (13.6")
Est. Ship Weight ..........Aluminum 33 kg (72 lbs)
Cast Iron 52 kg (114 lbs)
316 Stainless Steel 48 kg (106 lbs)
Air Inlet .................................19.1 mm (3/4")
Inlet ............................................ 51 mm (2")
Outlet ......................................... 51 mm (2")
Suction Lift ............................. 2.1 m Dry (7')
9.5 m Wet (28')
Displacement/Stroke ....... 1.89 l (0.50 gal.)
1
Max. Flow Rate ............... 606 lpm (160 gpm)
Max. Size Solids ...................19.0 mm (1/4")
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example:
To pump 322 lpm (85 gpm) against
a discharge pressure head of 2.1 bar (30 psig)
requires 4.1 bar (60 psig) and 94 Nm
3
/h (55
scfm) air consumption. (See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
[LPM]
Water Discharge Flow Rates
SECTION 5I
PERFORMANCE CURVES
T8 METAL STALLION ULTRA-FLEX™-FITTED
SECTION 5J
PERFORMANCE CURVES
T8 METAL STALLION TPE-FITTED