![Dover PSG WILDEN Pro-Flo SHIFT PS1 Engineering, Operation & Maintenance Download Page 9](http://html1.mh-extra.com/html/dover/psg-wilden-pro-flo-shift-ps1/psg-wilden-pro-flo-shift-ps1_engineering-operation-and-maintenance_2525046009.webp)
WIL-10470-E-05
9
PS1 Clamped Metal
PS1 METAL
PTFE-FITTED
Ship Weight…………….Aluminum 6 kg (13 lb)
316 Stainless Steel 9 kg (20 lb)
Alloy C 9.5 kg (21 lb)
Air Inlet…………………………….13 mm (1/2")
Inlet………………………………...13 mm (1/2")
Outlet………………………………13 mm (1/2")
Suction Lift……………………4.3 m Dry (14.2')
9.7 m Wet (31.7')
Disp. Per Stroke
1
…………..0.10 L (0.026 gal)
Max. Flow Rate…………..59.8 lpm (15.8 gpm)
Max. Size Solids……………….1.6 mm (1/16")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 17.4 lpm (4.6 gpm)
against a discharge head of 2.1 bar
(30 psig) requires 2.8 bar (40 psig) and
5.9 Nm
3
/h (3.5 scfm) air consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
For UL-listed pumps, do not exceed 3.4 bar (50 psig) air supply pressure.
PERFORMANCE