WIL-10183-E-03
Wilden
®
9
PERFORMANCE
P4 METAL
REDUCED STROKE
PTFE-FITTED
Ship Weight ........ Aluminum 13 kg (29 lb)
316 Stainless Steel 20 kg (45 lb)
Cast Iron 22 kg (49 lb)
Alloy C 23 kg (51 lb)
Air Inlet.................................. 19 mm (3/4")
Inlet .................................. 38 mm (1-1/2")
Outlet ................................. 32 mm (1-1/4")
Suction Lift ...................... 3.7 m Dry (12')
8.5 m Wet (28')
Disp. Per Stroke
1
.............. 0.53 L (0.14 gal)
Max. Flow Rate ............ 295 lpm (78 gpm)
Max. Size Solids ................. 4.8 mm (3/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 83 lpm (22 gpm)
against a discharge pressure head of
2.7 bar (40 psig) requires 4.1 bar (60 psig)
and 34 Nm
3
/h (20 scfm) air consumption
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
P4 METAL
FULL STROKE
PTFE-FITTED
Ship Weight ........ Aluminum 13 kg (29 lb)
316 Stainless Steel 20 kg (45 lb)
Cast Iron 22 kg (49 lb)
Alloy C 23 kg (51 lb)
Air Inlet.................................. 13 mm (1/2")
Inlet .................................. 38 mm (1-1/2")
Outlet ................................. 32 mm (1-1/4")
Suction Lift .................... 6.4m Dry (21.0')
9.3 m Wet (30.6')
Disp. Per Stroke
1
.................. 1.1 L (.28 gal)
Max. Flow Rate ......... 330 lpm (87.2 gpm)
Max. Size Solids ................. 4.8 mm (3/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 257 lpm (68 gpm)
against a discharge head of 1.4 bar
(20 psig) requires 4.1 bar (60 psig) and
96.5 Nm
3
/h (60 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.