WIL-11070-E-16
9
P200 Bolted Plastic
SECTION 5
P200 PLASTIC
RUBBER-FITTED
Ship Weights.……Polypropylene 10 kg (22 lb)
PVDF 15 kg (32 lb)
Air Inlet………………………..…….6 mm (1/4")
Inlet…...…………………...…………25 mm (1")
Outlet………………...………………25 mm (1")
Suction Lift……………………3.6 m Dry (11.9’)
9.1 m Wet (30.0’)
Disp. per Stroke
1
……..….......0.32 L (.086 gal)
Max. Flow Rate……………..220 lpm (58 gpm)
Max. Size Solids……………...4.76 mm (3/16")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2 bar (30
psig) head pressure.
Example:
To pump 68 lpm (18 gpm) against
a discharge head of 3.4 bar (50 psig) requires
4.1 bar (60 psig) and 34 Nm
3
/h (20 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure on Polypropylene and PVDF pumps.
P200 PLASTIC
TPE-FITTED
Ship Weights.……Polypropylene 10 kg (22 lb)
PVDF 15 kg (32 lb)
Air Inlet………………………..…….6 mm (1/4")
Inlet…...…………………...…………25 mm (1")
Outlet………………...………………25 mm (1")
Suction Lift……………………3.6 m Dry (11.4’)
9.8 m Wet (32.0’)
Disp. per Stroke
1
……..….......0.33 L (.088 gal)
Max. Flow Rate……………..216 lpm (57 gpm)
Max. Size Solids……………...4.76 mm (3/16")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 76 lpm (20 gpm) against
a discharge head of 3.1 bar (45 psig) requires
4.1 bar (60 psig) and 34 Nm
3
/h (20 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure on Polypropylene and PVDF pumps.
PERFORMANCE