valve to control flow as this can/will lead to 

“starving” the pump, causing cavitation and 

vibration that can result in damage to the 

pump  

5.  Ensure that all flushing and cooling lines, as 

applicable, are attached and operational. 

6.  Open vent / by-pass line valve (if applicable) 

7.  Depending on the system design, either 

adjust the discharge valve to be “cracked” 

open or keep it fully closed during priming 

8.  Start the driver 

9.  Listen for any unexpected noise and check 

for any significant vibration or indications of 

binding.  If any of these are observed, the 

pump should be stopped immediately, and a 

thorough check of the installation should be 

made to determine the cause.  Correct any 

fault(s) prior to re-starting the pump.  

10. Depending on the quantity of air that needs 

to be evacuated from the suction piping and 

the suction lift height, it can take up to 

several minutes to achieve full prime of the 

suction piping and pump. Contact either 

Griswold Pump Company or your local 

authorized Griswold representative for 

additional information in estimating suction 

system priming times.  

11. Monitor the gauges on the pump to 

determine when full prime has been 

achieved. Gradually adjust the discharge 

valve to allow the system to fill and stabilize 

at the pump’s operating capacity and head.  

Model

 

Initial Charge Volume 

(in

3

)

 

811SP 1.5x1-6 

310 

811SP 1.5x1.5-8 

390 

811SP 2x2-10 

1100 

811SP 3x3-10 

1160 

811SP 4x4-10 

1550 

811SP 3x3-13 

1330 

811SP 4x4-13 

1410 

811SP 6x6-13 

2980 

Table A – 811SP Series  

Minimum Initial Charge Volumes 

NOTE:

 During the priming process the suction 

liquid level is drawn up into the pump as the 

pump evacuates the air out of the suction line. 

Therefore, care must be taken to ensure that no 

air is leaking into the suction line, otherwise the 

pump will not achieve prime. 

REPAIR, ROUTINE MAINTENANCE,  

SPARE PARTS 

 

For instructions on pump repair, routine 

maintenance, and spare parts, see the Griswold 

811 ANSI Series IOM: 

https://www.psgdover.com/docs/default-

source/griswold-docs/ioms/811_iom.pdf, pages 

21-37. 

 

Summary of Contents for PSG Griswold 811SP Series

Page 1: ...GRS 18000 E 01 Where InnovationFlows IOM INSTALLATION OPERATION MAINTENANCE MANUAL 811SP SERIES Self Priming Centrifugal Pumps ...

Page 2: ...ERATION 4 Priming the Pump 4 REPAIR ROUTINE MAINTENANCE SPARE PARTS 5 APPENDIX 6 Impeller Clearance Chart 6 Pressure Temperature Ratings 6 Interchangeability 7 811SP Series Small Frame Group Pump Cross Sectional 8 811SP Series Medium Frame Group Pump Cross Sectional 8 811SP Series Large Frame Group Pump Cross Sectional 9 Parts and Material Composition 10 ...

Page 3: ...details see the Griswold 811 ANSI Series IOM available on our website https www psgdover com docs default source griswold docs ioms 811_iom pdf General Safety Do not allow pump piping or other components containing water to freeze Freezing may damage the components leading to possible injury or flooding Periodically inspect pump and associated components Wear safety glasses when working on pumps K...

Page 4: ...manual priming procedure prior to startup aside from the initial charge of liquid for the case priming chamber During the priming stage the self priming pump transfers air from the suction side to the discharge side of the pump drawing a vacuum on the suction side and lifting the liquid up the suction pipe An accumulation of air in the discharge piping hinders this process and can stall priming pr...

Page 5: ... of the suction piping and pump Contact either Griswold Pump Company or your local authorized Griswold representative for additional information in estimating suction system priming times 11 Monitor the gauges on the pump to determine when full prime has been achieved Gradually adjust the discharge valve to allow the system to fill and stabilize at the pump s operating capacity and head Model Init...

Page 6: ... 300 F 0 012 Up to 300 F Up to 350 F 0 014 Up to 350 F Up to 400 F 0 015 Up to 400 F Up to 450 F 0 016 Up to 450 F Up to 500 F 0 017 Up to 500 F Table B 811SP Series Impeller Clearances at Ambient for Various Service Temperatures Pressure Temperature Ratings Chart A specifies the maximum allowable working pressure for 811SP Series pumps given the pump material of construction and the pumping tempe...

Page 7: ...ty Griswold 811SP Series pumps are designed to be easy to maintain and repair Many of the pump components can be interchanged between the models in order to maximize interchangeability with the portfolio to help simplify inventory and reduce costs ...

Page 8: ...GRS 18000 E 01 8 811SP SERIES 811SP Series Small Frame Group Pump Cross Sectional 811SP Series Medium Frame Group Pump Cross Sectional LG1901 Rev A LG1902 Rev A ...

Page 9: ...GRS 18000 E 01 9 811SP SERIES 811SP Series Large Frame Group Pump Cross Sectional LG1903 Rev A ...

Page 10: ...4MCuN 316 SS Alloy 20 228 1 Frame Cast Iron 240 1 Spacer Frame Foot Spacer Steel 241 1 Frame Foot Small Frame Steel 1 Frame Foot Medium Large Frame Cast Iron 250 1 Mechanical Seal Gland Alloy 20 316 SS Alloy 20 319 1 Sight Oil Gauge Cadium Plated 332A 1 Labyrinth Oil Seal Outboard Bronze Optional Carbon Filled PTFE 333A 1 Labyrinth Oil Seal Inboard Bronze Optional Carbon Filled PTFE 351 1 Casing G...

Page 11: ...________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ___________________________________________________________________...

Page 12: ... USA P 1 909 512 1262 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document GRS 18000 E 01 Where InnovationFlows ...

Reviews: