7.9.6 System/Alarms

The System/Alarms report shows the alarms for the last seven days.

7.10 Configuration

Push the

Shifts

icon on the

Main Menu

, enter your

Password

at the prompt and the "Shifts" screen will

come into view.

7.10.1 System Configuration

Push the

System

icon on the

Configuration Menu

and the "Network Settings" screen will come into view.

l

Select a

parameter

to change. A keypad will come into view.

M2052-EU Rev.: 1 Dover Fueling Solutions

Page 25

Summary of Contents for ProGauge MagLink LX

Page 1: ...Part Number M2052 EU Rev 1 Issue Date V User s Manual MagLink LX M2052 EU Revision 1 ...

Page 2: ...oGauge is a part of Dover Fueling Solutions Contact START ITALIANA S r l Via Pola 6 20813 Bovisio Masciago MB Italy Tel 39 0362 1581465 Fax 39 0362 1581464 Copyright Information 2020 Dover Fueling Solutions All rights reserved DOVER the DOVER D Design DOVER FUELING SOLUTIONS and other trademarks referenced herein are trademarks of Delaware Capital Formation Inc Dover Corporation Dover Fueling Solu...

Page 3: ...ection 6 Product Labels 14 Section 7 Graphical User Interface 15 7 1 Inventory 15 7 1 1 Status Icons 16 7 2 Main Menu 19 7 3 Status Page 19 7 4 Calendar 20 7 5 Notifications 20 7 6 History 21 7 7 Maintenance 21 7 8 Shifts 22 7 9 Reports 23 7 9 1 Sales Report 23 7 9 2 Shift Report 23 7 9 3 Delivery Report 24 7 9 4 Leakage Report 24 7 9 5 History 24 7 9 6 System Alarms 25 M2052 EU Rev 1 Dover Fuelin...

Page 4: ...7 10 Configuration 25 7 10 1 System Configuration 25 7 10 2 Tank Configuration 26 Section 8 Technical Support 27 M2052 EU Rev 1 Dover Fueling Solutions Page 4 ...

Page 5: ...vements and or changes in the product and or associated programs Start Italiana S r l is not liable for damages of any kind including those resulting in the document including typographical errors Making copies citing quotes or other reproductions of all or part of this document is permitted only after written consent of Start Italiana S r l Patents protect trademark or name Copyright 2019 Start I...

Page 6: ...service provider or manufacturer The manufacturer is not liable for injury and or damage to persons and or property and or pets caused by the failure to obey safety instructions All approved personnel must know all safety requirements in this manual the configuration manual and the user manual Refer directly to an approved service provider or manufacturer for questions about the operation of the e...

Page 7: ...guration Manual and use the console in the field as shown in this manual WARNING This device must not be discarded with household waste This device is labeled in accordance with European Directive 2012 19 UE concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE This guideline gives the methods for the return and recycling of used electronic devices as ...

Page 8: ...ement contained in this manual refer to a specified selection by the user Refer to the M2051 EU MagLink LX Configuration Manual for more information on how to set units of measure M2052 EU Rev 1 Dover Fueling Solutions Page 8 ...

Page 9: ...ard can have 8 relay outputs 8 digital inputs or 4 20mA These cards can be put together so that the system can have 32 relays and 0 inputs 32 inputs and 0 relays and a mixture of both in increments of 8 The console can interface with a site s FCC POS through serial or Ethernet connection The console has a resistive type touchscreen that can be used with fingers also with gloves stylus pens for tou...

Page 10: ...p to 32 Internal relay outputs 4 Lower power of the relay output 0 5 A 33 V or 2 A 30 V DC Output power for the probes 12 V DC 100 mA per output for each probe connectors MR3 MR4 up to 8 probes for each connector Serial communication of the probes RS485 Host communication management RS232 and TCP IP almost every forecourt controller have the protocol integrated Printer communication RS232 Integrat...

Page 11: ... DMP IS 485 NOTE ALL the floats used on probes have more than 10 years of life time in the fuel tanks Auxiliary equipment that can be used with the MAGLINK LX console include l Expansion cards up to 32 relays and 0 inputs up to 32 inputs and 0 relay and a mixture of both in increments of 8 l Local Printer M2052 EU Rev 1 Dover Fueling Solutions Page 11 ...

Page 12: ...ent to this manual and users must acknowledge it before using the equipment WARNING The Console must not be used in hazardous areas because there is a risk of fire and explosion The probes of the XMT SI 485 family are installed in hazardous areas and must be connected to the Barrier contained in the console 4 3 Incorrect Use Incorrect and alternative uses include l Resistive touch screen Only use ...

Page 13: ...h the power button to the ON position 1 If the console is not configured when it is energized it will cause an alarm because it does not communicate with a tank Push the red arrows up or down until you see the page ALARM LOG Push the ACK button to stop the alarm To make changes to the console configuration refer to the MagLink LX Configuration Guide M2051 EU To de energize the console push the pow...

Page 14: ... and Hz l Power consumption VA l Operating temperature C l Ingress protection IP grade l Fuse rating l Indication that inside there is intrinsically safe circuit l Name and address of the manufacturer l Equipment Type BRA SIP or BRA 2SIP l ATEX Reference number of the certificate l ATEX Marking Ex II 1 G Exia IIB FISCO power supply UM 250 V Exia IIB l Serial number l Electrical data M2052 EU Rev 1...

Page 15: ...reen will open that shows information related to the categories in the tables that follow Volume Product Gross Product volume at the current temperature includes the water volume Comp prod Compensated product volume temperature at 15 C or 20 C refer to the configuration Water Current water volume Ullage Empty space calculated from the safe working capacity refer to the configuration Capacity The t...

Page 16: ... installed Density Density The density at current temperature Weight The weight of the product calculated by the measured density Temperature Current The current product temperature Compensated The temperature setting that is used for volume compensation refer to the con figuration 7 1 1 Status Icons Status OK Green No Alarm l The Traffic Light is green l There are no Alarms l The NO ALARM button ...

Page 17: ... Acknowledge Alarm button to aknowledge the alarm in the system Status Alarm HH H Yellow Alarm Aknowledged l The Traffic Light is yellow l The alarms HH High High and H High have been acknowledged l The color in the related fields is changed to yellow l The ACKNOWLEDGED button is grayed out TIP Move your finger down the display to see the next screen M2052 EU Rev 1 Dover Fueling Solutions Page 17 ...

Page 18: ...s There are four 4 action button selections l Diagnostic l Email Inventory l Print Inventory l SMS Inventory TIP Move your finger down the display to see more tank settings and the Strapping table M2052 EU Rev 1 Dover Fueling Solutions Page 18 ...

Page 19: ...ain Menu The display will navigate to the Status screen that shows information related to the condition of the Tanks or Sensors move the Sensor slider to the right to see the Sensor status The icons will show in green if there are no alarms If a tank or sensor is in alarm its icon will show in red M2052 EU Rev 1 Dover Fueling Solutions Page 19 ...

Page 20: ...ted to the console l Select this icon to show events related to tanks l Select this icon to show events related to sensors l Select this icon to show deliveries l Select this icon to show alarms l Select this icon to show warnings l Select this icon to show leak tests Use the radio buttons along the right side of the calendar to select the applicable tanks Push a date box to see information for th...

Page 21: ...r a selected period 7 7 Maintenance Push the Maintenance icon on the Main Menu and the Maintenance screen will come into view In this screen you can l Do software updates through the use of a USB thumb drive The user must n Get the update file lx4_new zip from Dover Fueling Solutions n Copy it onto a USB thumb drive n Put the thumb drive into the USB port on the console n Push the Read update from...

Page 22: ...e entered before you can proceed NOTE Note The password is set up on the web configuration page refer to Passwords in M2051 EU MagLink LX Configuration Manual REMINDER Only an Admin user can set or change a password 7 8 Shifts Push the Shifts icon on the Main Menu and the Shifts screen will come into view The shifts from the last three days will show Select the Close shift button to manually close...

Page 23: ...hown in the screen image above 7 9 1 Sales Report The sales report shows the daily tank sales for the last seven days 7 9 2 Shift Report The shift report shows a full report of each shift for the last seven days The report shows the deliveries and tank sales that occurred during the shift M2052 EU Rev 1 Dover Fueling Solutions Page 23 ...

Page 24: ...ast seven days 7 9 4 Leakage Report The Leakage report shows all of the leak test results for the last seven days 7 9 5 History The History report shows the inventory data of each tank The console stores the inventory of every tank for every minute M2052 EU Rev 1 Dover Fueling Solutions Page 24 ...

Page 25: ... on the Main Menu enter your Password at the prompt and the Shifts screen will come into view 7 10 1 System Configuration Push the System icon on the Configuration Menu and the Network Settings screen will come into view l Select a parameter to change A keypad will come into view M2052 EU Rev 1 Dover Fueling Solutions Page 25 ...

Page 26: ...You can make changes to Tank configuration parameters in this screen see the image above When you have completed all necessary changes Click Save Click the button to go to the Protocol Settings screen You can make changes to the Serial and TCP IP port parameters in this screen see the image below Push the Exit button to navigate from this screen to go back to the Configuration menu M2052 EU Rev 1 ...

Page 27: ... steps to send this data to Technical Support IMPORTANT You must have a USB device with at least 50 MB of free space available The USB device must be formatted to FAT32 Connect the USB device to a PC Put a new folder on the USB device and give it the name lx support make sure you use lower case Eject the USB device from the PC Connect the USB device to the console see General Indications for the l...

Page 28: ...ective Software Version Key Changes 0 1785 8 19 2020 Initial Release 1 1836 12 3 2020 Adds Settings and Shifts NOTE It is possible that older software versions might not support all features M2052 EU Rev 1 Dover Fueling Solutions Page 28 ...

Page 29: ......

Reviews: