3.2.1 Install the Flange
DANGER: Do not use electric or battery operated power tools!
To avoid
the possibility of explosion or fire, when you install these components near the
Hazardous Area, use pneumatic tools only. Be sure your system is completely
de-energized before you do the installation.
DANGER:
Make sure that the pole used to install the antenna is not
grounded to the terminal or other system components.
Make sure the antenna is isolated from the pole. Use a non-conductive
material between the antenna bracket and the metal pole.
l
Install the flange so the pole will be close to the left side of the pedestal. Use the correct bit and
fasteners for the material where the flange is installed.
Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions
18