background image

TaskMizer

Dual Select

with E-Gap Eductors

and Remote Fill

Model  48781

TROUBLESHOOTING CHART:

Problem

Cause

Solution

1. No discharge

a. No water

a. Open water supply

b. Magnetic valve not functioning

b. Install valve parts kit

c. Excessive water pressure

c. Install regulator if flowing water pressure

exceeds 60 PSI

d. Eductor clogged

d. Clean* or replace

e. Low flow mechanism failure

e. Install new parts

f. High flow mechanism out of

f. Adjust cable tension by loosening lock nut and

adjustment

increasing tension on cable. Retighten lock
nut.

g. Cable extremely loose/broken. Order

g. High flow mechanism broken

replacement gun/cable assembly.

h. Clogged water inlet strainer

h. Disconnect inlet water line and clean strainer.

2. No concentrate draw

a. Clogged  foot strainer

a. Clean or replace

b. Metering tip or eductor has scale

b. Clean (descale)* or replace

build-up

c. Low water pressure

c. Minimum 25 PSI (with water running)

required to operate unit properly

d. Discharge tube and/or flooding

d. Push tube firmly onto eductor discharge

ring not in place (high flow only)

hose barb, or replace tube if it doesn't have
a flooding ring

e. Concentrate container empty

e. Replace with full container

f. Clogged water inlet strainer

f. Disconnect inlet water line and clean strainer

g. Selector out of position

g. Assure selector is in position desired

h. Check valve installed backwards

h. Confirm colored side is pointed toward eductor

i. Air leak in chemical pick-up tube

i. Put clamp on tube or replace tube if brittle

j. Clear plastic tip installed in inlet

j. Replace with colored metering tip

hose barb

3. Excess concentrate draw a. Metering tip not in place

a. Press correct tip firmly into barb on select  valve

4. Failure of unit to turn off

a. Water valve parts dirty or defective

a. Clean* or replace with valve parts kit

b. Magnet doesn't fully return

b. Make sure magnet moves freely.

Replace spring if short or weak

c. Excessive water pressure

c. Install regulator if pressure (with water

flowing) exceeds 60 PSI

d. Mechanism hangs up

d. Be sure bracket is free to move and not broken

5. Excess foaming in

a. Air leak in chemical pick-up tube

a. Put clamp on tube or replace tube if brittle

discharge

Package Should Contain:
1.  Proportioner unit with discharge tubes.
2. (2) lengths of chemical inlet tubing,

1/4" x 21' & 1/4" x 14'.

3.  Mounting Bracket.
4. Dispensing Gun.
5. Accessory kit containing:

(2) "Y" hose barbs,(6) in-line check
valves, (4) weights, (4) foot strainers,
(2) metering tip kits, (3) mounting
screws and (3) anchors.

6. Instruction sheet.

3798 Round Bottom Road, Cincinnati, OH 45244 U.S.A. • Phone: (513) 271-8800  Fax: (513) 271-0160 • www.hydrosystemsco.com

10088626 Rev. A

9/00

Ins

tallation and Operation:

1.   Find suitable place close to water source for unit. Mounting bracket should be installed  approx. 5' from floor. Level bracket

& mark holes. Drill 9/32" holes & install mounting anchors and screws in bracket.

2.  Hang cabinet on bracket. Mark hole for lower cabinet screw. Remove cabinet  &  drill 9/32" hole. Install anchor and
     screw to lower unit hole. When mounting unit do not mount any higher than 5 feet from the floor. Also, never mount
     your concentrate container higher than the unit.

3. Select 4 metering tips for the selector valve attached to the low flow (gray) eductor, and 2 tips for the select valve attached

to the high flow (yellow) eductor. Push each tip firmly into a separate hose barb extending from the selector valve.
NOTE: The two hose barbs on the select valve attached to the high flow (yellow) eductor have been blocked with clear
tips for dispensing water. These may be replaced with colored metering tips if
additional high flow products are desired. NOTE: additional pickup lines will be needed.

4. Cut tubing provided into separate supply tubes for each product to be dispensed.

Supply tubes should reach from hose barbs on the selector valve body to bottom of
concentrate containers.  Slide ceramic weights over one end of each tube
and slide foot strainer into the same ends of the tubes. Remember  to include check
valves in the proper places in the supply tubing, colored end facing eductor body, as
shown (see diagram  Page 3). Additional tubing is provided for drain hole in bottle fill
drip tray. NOTE: When routing pickup line(s) through unit, direct pickup line
through clip(s) in cabinet back to ensure proper operation. (see diagram1)

5. Place strainer ends of supply tubes into concentrate containers. REMEMBER

TO CHECK STRAINERS PERIODICALLY FOR CLOGGING:CLEAN IF NECESSARY.

        DIAGRAM 1

6. Replace unit cover. Be sure cover is labeled to allow identification of products to be dispensed.
7. Connect water supply hose to water inlet swivel. (Minimum 25 PSI pressure, with water running, is required for proper

operation.) Turn on water supply.

8. Purge air from system by repeated rapid depressions of activating devices. The bottle fill activates by inserting a spray

bottle over the discharge tube and lifting lever until flow starts. To stop flow, lower bottle off discharge tube. The bucket
fill activates by holding and depressing lever of gun. To stop flow, release lever. The lever can be locked on by flipping
clip to hold lever. CAUTION: Lever must be manually unlocked to stop flow. Overflow will result if left locked
in open position.

* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are

exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove
an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively,
a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit
with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by
drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS

protective clothing and eyewear when dispensing chemicals or other materials.

observe safety and handling instructions of the chemical manufacturers.

direct discharge away from you or other persons or into approved containers.

dispense cleaners and chemicals in accordance with manufacturer's instructions.
Exercise  CAUTION when maintaining your equipment.

equipment  clean to maintain proper operation.

protective clothing and eyewear when working in the vicinity of all chemicals, filling or
emptying equipment or changing metering tips.

re-assemble equipment according to instruction procedures. Be sure all components
are firmly screwed or latched into position.

only to tap water outlets (85 PSI maximum).

If the unit is used to fill a sink or the discharge hose can be placed into a sink, the unit
must be mounted so that the bottom of the cabinet is above the overflow rim of the sink.

WEAR

ALWAYS

ALWAYS

ALWAYS

KEEP

WEAR

ALWAYS

ATTACH

Hydro Systems manufactures quality chemical proportioning equiment. Please use this equipment
carefully and observe all warnings and cautions.