background image

Page 15

Hydro Systems Co. 2019

HYD10099044  Rev 1.4

Clean pickup tube, removing any film, particles, dirt that 

may have built up.

Clean inside of tank and lower the pickup tube back into 

the tank 

WARNING TAKE CARE NOT TO DROP THE 

PICKUP HOSE INTO THE WATER TANK

5

6

Replace securing clip back onto pickup tube 

WARNING 

TAKE CARE NOT TO DROP THE SECURING CLIP INTO 

THE WATER TANK

Replace rear cover

7

8

Clean the inlet strainer washer on the EvoBoost:

1. EVB1561230VB (230 VAC)

2. EVB1561115VG (115 VAC)

clean

clean

Summary of Contents for HYDRO EvoBoost

Page 1: ...user manual EvoBoost ...

Page 2: ...ifications 6 5 installation 7 5 1 Site surveys and installation requirements 7 5 2 Installation for up to 3x EvoClean dispensers 8 6 set up 11 7 operation 12 8 maintenance 12 9 troubleshooting 14 10 spares and repair 15 11 warranty 16 12 decommissioning and disposing 16 13 electrical approvals 16 14 water approvals 17 15 WEEE waste electrical electronic equipment 17 ...

Page 3: ...inst the Contents of Packaging before starting installation Any alterations made to the EvoBoost and fittings will invalidate the Warranty Overview The EvoBoost is a sleek booster tank that compliments OPL installs The system is designed to mitigate poor water pressure and flow that can impact the performance of Laundry Chemical dispensers With the EvoBoost installed chemical delivery will be cons...

Page 4: ...nnection of the appliance from the supply mains must be incorporated within the fixed wiring in accordance with the wiring rules if the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons to avoid a hazard this unit is not to be used in an ATEX environment ensure unit overflow is connected to a drain point WEAR the appropriate protective ...

Page 5: ... the floor near the chemical containers and has a clean aesthetic The air gap on the water inlet of the EvoBoost provides a physical air break between the incoming potable water supply and the main water reservoir Although it has been designed for a laundry use case the EvoBoost is versatile and flexible to be used with any venturi dispenser The EvoBoost pump will run when a valve on the dispenser...

Page 6: ...bs 6 2kg 13 7lbs EVB1561230VB 230 V AC 0 4 Class I 3 contents of packaging Packaging contains Item Description EVB1561230VB EVB1561115VG 1a EvoBoost 1x 1x 2a Strainer Washer 1x 1x 3a 15mm Double Check Valve 1x 4a Waste Pipe Elbow 1x 1x 1a 2a 3a 4a For installation kits and spare parts please see page 17 NOTE Back pressure on the outlet of the pump is not to exceed 4 8 bar 70 psi dynamic CAUTION Th...

Page 7: ... that the proposed site meets the following requirements Ensure the flooring to mount the EvoBoost is of solid construction stable level and can accommodate the weight of the product when filled with water 26kg 57lbs There is a 115 230V mains supply available within 3 meters 10ft of the installation location There is a mains water supply available within 2 meters 6 5ft of the installation location...

Page 8: ...ts are listed within the manual please contact your local sales representative for further information Please ensure the distances between the EvoClean dispensers and EvoBoost unit are adhered to in order to maintain correct operation Minimum pipe internal diameter should be 8mm Anything smaller may affect function wash results Ensure all plumbing connections are tightened sufficiently sealed corr...

Page 9: ...ICRON CUSTOMER SUPPLIED WATER MAIN EVB1561230VB 230V BSP EVB1561230VB 230V BSP WATER FILTER 105 MICRON CUSTOMER SUPPLIED WATER MAIN B B A CONNECT OVERFLOW TO DRAIN CONNECT OVERFLOW TO DRAIN B A Max horizontal distance from Point A to Point B is 3m 10ft Max horizontal distance from Point A to Point B is 3m 10ft 3 1 4 2a 1a 2 5 2 3 6 3a 4a 4a ...

Page 10: ...n EVB1561115VG 115V GHV Max horizontal distance from Point A to Point B is 3m 10ft WATER FILTER 105 MICRON CUSTOMER SUPPLIED WATER MAIN B B A CONNECT OVERFLOW TO DRAIN B Max horizontal distance from Point A to Point B is 3m 10ft WATER FILTER 105 MICRON CUSTOMER SUPPLIED WATER MAIN 3 4 2a 1a 1 5 3 3 7 7 MAX 1 6M 5 5FT 9 4 2a 1a 9 10 CONNECT OVERFLOW TO DRAIN 3a 4a 4a ...

Page 11: ...EVB1561115VG 115V GHV EVB1561115VG 115V GHV Max horizontal distance from Point A to Point B is 3m 10ft Max horizontal distance from Point A to Point B is 3m 10ft WATER FILTER 105 MICRON CUSTOMER SUPPLIED WATER MAIN MAX 1 6M 5 5FT MAX 1 6M 5 5FT 9 4 2a 1a 9 10 4 2a 1a 9 10 9 9 9 10 10 10 CONNECT OVERFLOW TO DRAIN CONNECT OVERFLOW TO DRAIN 4a 4a WATER FILTER 105 MICRON CUSTOMER SUPPLIED WATER MAIN ...

Page 12: ...within the fixed wiring in accordance with the wiring rules The installer and user are responsible for ensuring the installation and operation of the EvoBoost EvoClean units are in accordance with this Installation and User Manual and EvoClean manual and local and national regulations If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified per...

Page 13: ...4 8 bar 70 psi or there is too much backpressure for the pump to operate properly The plumbing between the EvoBoost and EvoClean will pressurise until the pressure switch on the pump cuts out Check for leaks in the system plumbing between the EvoBoost and EvoClean Using the prime chemicals feature on the EvoClean operate the flush valve for approximately 30 seconds to flush through any trapped air...

Page 14: ...hout constant interruption Check inlet outlet plumbing to ensure not leaks have formed Clean the unit with a damp cloth and remove dust lint and dirt Every 3 Months 8 maintenance ENSURE BOTH THE EVOBOOST THE EVOCLEAN UNITS ARE ISOLATED POWER WATER AND DE PRESSURISED BEFORE SERVICING OR MAINTAINING EITHER UNIT Every 6 Months Clean the pump pickup tube use a cleaning tablet to clean the inside of th...

Page 15: ...lower the pickup tube back into the tank WARNING TAKE CARE NOT TO DROP THE PICKUP HOSE INTO THE WATER TANK 5 6 Replace securing clip back onto pickup tube WARNING TAKE CARE NOT TO DROP THE SECURING CLIP INTO THE WATER TANK Replace rear cover 7 8 Clean the inlet strainer washer on the EvoBoost 1 EVB1561230VB 230 VAC 2 EVB1561115VG 115 VAC clean clean ...

Page 16: ...ering chemical or inadequate flushing EvoBoost not connected to power source or not turned on Check EvoBoost unit is connected correctly to the mains power supply Tank has run out of water Ensure water supply to EvoBoost is on and there is sufficient flow and pressure see specification Inlet strainer washer to EvoBoost may have blocked Clean inlet strainer washer as per Maintenance section of the ...

Page 17: ...YD10099188 HYD10099189 HYD10099190 1 BSP Water Hose Straight 1x 1x 2x 2 BSP Water Hose 90 Elbow 1x 2x 3x 3 BSP Nipple 1x 2x 3x 4 Strainer Washer 1x 1x 1x 1x 1x 1x 5 BSP x 15mm Tee Valve 1x 1x 3x 6 BSP Y Piece Adaptor 1x 7 15mm Adaptor Elbow 2x 8 BSP x 15mm Straight Valve 2x 9 Hose 3 8 ID 2x 3x 5x 10 Brass Y Piece Adaptor 1x 2x 3x 10 spares accessories Install kits Install kits are available for bo...

Page 18: ...facture This limited warranty does not apply to a hoses b and products that have a normal life shorter than one year or c failure in performance or damage caused by chemicals abrasive materials corrosion lightning improper voltage supply physical abuse mishandling or misapplication In the event the Products are altered or repaired by Buyer without Seller s prior written approval all warranties wil...

Page 19: ...e Low Level Alarm unit is a product placed onto market POST 13 08 05 therefore called future WEEE As a producer Hydro Systems Europe have the option to take responsibility for the EEE placed on the market If Hydro Systems Europe chooses to receive WEEE they must make sure that it is disposed of in an environmentally sound way including the treatment reuse recovery and recycling of the components w...

Page 20: ...513 271 88OO contact hydro hydrosystemsco com www hydrosystemsco com Europe 44 O1344 48888O info hydrosystemseurope com www hydrosystemseurope com Asia Pacific 86 21 6187 1O3O sales hydro hydrosystemschina com www hydrosystemschina com ...

Reviews: