10
Rinse Injector After Each Use
Additive allowed to remain in injector can dry, foul or
damage the lower end at the next start-up. Place suction
tube into a 1 qt. (0.95 liters) or more container of fresh
filtered water. Flow fresh water through the injector by
operating until container is empty. This procedure is not
needed for continuous operation.
Clean Solution Container
Keep covered to prevent dirt, flies, feathers and other
flying debris from entering the container. Rinse container
thoroughly and often. Do not mix chemicals together that
might react and cause a precipitate. Use FILTERED fluid
when filling container.
Clean Suction Tube Filter Screen
Inspect each time new solution is added. Clean filter
screen (#27) and suction tube (#25) as necessary by
rinsing in fresh water. Replace if necessary. Keep filter
screen off bottom of solution container to prevent dirt
and precipitate from clogging filter.
Clean Inlet Filter
Clean or replace inlet filter as required to increase the life
of the unit as well as reduce pressure loss.
Bypass Injector
When not in use place the injector in bypass mode by
using the three valve bypass (preferred) or turn the
On/Off lever on the top of the injector to the off position.
Storage
For extended storage, rinse injector (see “Rinse Injector
After Each Use”) and place underwater in a container.
Apply monthly, <0.1 oz. (29 ml) of chlorine bleach to
avoid algae growth. KEEP FROM FREEZING.
Remote Injector Kit (not included)
Is recommended for the following:
Injectors In a Series:
When injecting multiple chemical injections, using two or more
injectors. Each injector adds chemical to the fluid(water) system,
while bypassing the next injector and eliminating the potential
damage to that injector (see Fig. 6). To prevent mineral buildup
within the body of the unit. Use when injecting chemicals that
cause minerals to precipitate from fluid.
NOTE: When mixing more than one chemical, always refer
to your chemical manufacturer information guide for proper
application. Contact your local distributor or Hydro Systems
customer service for information or to order.
Fig. 6
Remote
Injector Kit
shown in
a series.
Perform these maintenance
procedures to extend the life of your unit.
Every
3 - 6 Months
Every
6 - 12 months
Replace as
necessary
1. Clean seal area (#13).
2. Check #17 O-ring,
#51 Shaft Assembly,
clean and/or replace
as necessary.
1. Replace #17 O-ring and
#51 Shaft Assembly.
2. Clean and/or replace
#13 Check Poppet, #11
Suction Tube Fitting.
1. #37 Cylinder
2. #17 O-ring
3. #51 Shaft
MiniDos (0.4%)
Refer to pages
18 & 19
Reference numbers refer to Page 17 - 24
Kit Part Numbers
011762
Every
3 - 6 Months
Every
6 - 12 months
Replace as
necessary
1. Clean seal areas (#
17, 14 & 13).
2. Check #17 O-ring,
# 68 Cylinder, clean
and/or replace
as necessary.
1. Replace #17 O-ring and
#44 Dosage Piston.
2. Clean and/or replace
#13 Check Poppet, #11
Suction Tube Fitting.
1. #68 Cylinder
2. #14, #17 O-ring
3. #51 Shaft
4. #44 Dosage Piston
MiniDos (1%)
Refer to page 20
Every
3 - 6 Months
Every
6 - 12 months
Replace as
necessary
1. Clean seal areas
(# 17, 14 & 13).
2. Check #17 O-ring,
#37 Cylinder, clean
and/or replace
as necessary.
1. Replace #17 O-ring and
#44 Dosage Piston.
2. Clean and/or replace
#13 Check Poppet,
#11 Suction Tube Fitting.
1. #37 Cylinder
2. #14, #17 O-ring
3. #52 Shaft
4. #44 Dosage
Piston.
Every
3 - 6 Months
Every
6 - 12 months
Replace as
necessary
1. Clean seal areas (#
17, 14 & 13).
2. Check #17 O-ring,
#37 Cylinder, clean
and/or replace
as necessary.
1. Replace #17 O-ring
and #44 Dosage Piston.
2. Clean and/or replace
#13 Check Poppet,
#11 Suction Tube Fitting.
1. #37 Cylinder
2. #14, #17 O-ring
3. #52 Shaft
4. #44 Dosage Piston
Every
3 - 6 Months
Every
6 - 12 months
Replace as
necessary
1. Clean seal areas
(# 17, 14).
2. Check #17 O-ring,
#7 Cylinder, clean
and/or replace
as necessary.
1. Replace #17 O-ring and
#44 Dosage Piston.
2. Clean and/or replace
#60.
1. #7 Cylinder
2. #14, #17 O-ring.
3. #44 Dosage Piston
MiniDos (2.5%)
& (5%) Refer to
pages 21 & 22
MiniDos (10%)
Refer to page 23
MiniDos (20%)
Refer to page 24
Remote
Injecting
Maintenance