Doulton EcoFast Installation Instructions Download Page 3

Prepare filter for use

1.    With the user faucet open, slowly turn on the mains water to allow the system to 

fill gradually and run the filtered water to waste for 10 minutes (or 15 litres).

2.   Close the faucet and check for leaks.

3.    Leave to stand for 24 hours to condition the ceramic filter element, then run 

water to waste for a further 10 minutes. The filter is now ready for use.

Servicing the filter -  removal of the filter element

1.    Grip the textured rim of the grey filter cap, twist to the ‘unlock’ position, taking 

care not to trap fingers and pull down to disengage -

 see figure 7

Note:

 If filter 

has had little use prior to servicing, twist to the ‘V’ vent position and open the user 
faucet (to relieve pressure in the filter) twist the grey cap to the ‘unlock’ position 
and pull down to disengage the filter whilst the faucet remains open.

2.    The water supply is automatically turned off when the filter is dismantled.  

Note:

 If filter is to be left unattended whilst dismantled for an extended period of 

time (i.e. over 1 hour) then the upstream mains water supply should be isolated. 

3.   Take the filter cartridge to the sink - remembering that it is still full of water.

4.    Unscrew filter cap to remove the filter body and empty the water into the sink, 

taking care not to contaminate the open ended neck of the filter cap with 
unfiltered water

5.    Disconnect the filter element by either twisting and pulling or unscrewing 

(depending upon the type of element used) whilst holding the filter cap. Care 
must be taken to prevent contamination of the neck of the filter cap and filter 
element mount stem.

6.    Replace the filter element or clean as described in the following section and then 

wash your hands.

 

Note:

 If replacing with a new filter element, prepare the filter for use as described 

in the ‘prepare filter for use’ stage above, or as per the Operating and Exchange 
Instructions supplied with the filter element.

Cleaning the filter element - figures 8 & 9

Due to filtration of particulate contaminants from the water during use, the flow of the 
water from the filter may reduce over a period of time. To restore the water flow to it’s 
normal level, simply clean the cartridge as follows:

Hold the filter element in a bowl of water or under running water, taking care to ensure 
that the open ended plastic mount is clear of the water - to avoid contamination - 

see 

figure 8.

Take a clean kitchen scouring pad in one hand and cup it around the circumference of 
the filter element at the top - next to the mount.

Press gently onto the candle surface with the kitchen pad, whilst quickly turning the 
element with the other hand.

Applying a gentle even pressure with the scouring pad slowly work down the length of 
the filter element once, ensuring that the cleaning is uniform over the whole candle - 

see figure 9.

Figure 7

Figure 8

Figure 9

www.doulton.com

Summary of Contents for EcoFast

Page 1: ...ation of the neck of the filter cap and stem of the filter element mount by contact with unfiltered water or dirty hands after cleaning the filter element surface Connecting Pipework and Fittings for either the 1 4 or 3 8 models The filter is supplied with pushfit connections Medium density polyethylene tubing from a reputable supplier is recommended An isolation valve and non return valve should ...

Page 2: ...10 Align the arrows to the unlock position and push the assembled filter firmly into the head until it clicks into position see figure 5 11 Twist the white filter body until the locked position on the head is reached see figure 5 12 Check that the arrows align to ensure that the filter is fully locked see figure 5 Select correct pipe for installation The filter is supplied in either 3 8 or 1 4 pus...

Page 3: ...th unfiltered water 5 Disconnect the filter element by either twisting and pulling or unscrewing depending upon the type of element used whilst holding the filter cap Care must be taken to prevent contamination of the neck of the filter cap and filter element mount stem 6 Replace the filter element or clean as described in the following section and then wash your hands Note If replacing with a new...

Page 4: ...ructural test criteria However due to the potential wide variations of pressures from one installation to another the manufacturer advises that if there is any concern that the system would see pressures above 6 bar then an approved pressure reducing valve set at 6 bar should be installed upstream of the filter to eliminate any extreme variations of pressure Note Water fittings for use in permanen...

Reviews: