Douglas Lighting Controls LitePak WPAK-33518-S Technical Data Download Page 1

7.1

Technical Data

B-7.1,2,3,4  -Auto, LitePak Panels

Components   7.1 

www.DouglasLightingControls.com

Programmable LitePak Panels 

L i t e P a k

PART No.

SPECIFICATION

DESCRIPTION

DIMENSIONS & MOUNTING

LitePak Panel Ratings

n

  LitePak panels use Douglas 2wire HID 

relays rated for all types of lighting loads. 

n

  120/277V Panels contain 8 or 16 relays.

  Rating:   20A @120/277V  UL
      20A @120/347V  CSA
  Max conductor size: 12 AWG

n

  277/480V panels contain 4 or 8, 2pole  relays.

  Rating:   20A @120/277/480V  UL
      20A @120/277/347V  CSA
  Max conductor size: 10 AWG

n

 Power supply:

  120/277V Transformer, Class 2, UL 
  120/347V Transformer, Class 2, CSA

LitePak Controller Module

n

  8 time and/or photo controlled outputs, 

each connected to a relay permitting  
each relay to have a unique program.   
Up to 4 relays can be controlled by an 
output to share the same program. 

Programming

n

  Membrane key pad with  LCD display 

graphic. Built-in prompts to guide users.

n

  Any output can be time, astro, photo 

controlled or combination of time and 
photo/astro controlled.

n

  Up to 900 events per week.

n

 Set any output schedule to run on any   

week day  (Su-Mo-Tu-W-Th-F-Sa) or on 
any specific date or dates (holidays).

n

  The controller's memory and time are   

not lost when power fails. Programs      
are held indefinitely and time is held for   
a minimum of 72 hours.

Sensor & Switch Options

n

  WPS-5527K Remote Photo Sensor.

  Range: 0 to 6,500 fc (0-65,000 lux), ±5%;

  

 

Using sensor, any output can be set to 
switch at a specific light level.

  (eg1:  ON 5fc; OFF 15fc Dusk-to-Dawn)
  (eg2: ON 2000fc; OFF 4000fc  Skylight)

n

  For remote switching, use any model of 

Douglas 2wire relay switch. 

Environment

n

  Indoors, stationary, non-vibrating, non-

corrosive atmosphere and non-
condensing humidity.

n

  Ambient operating temperature:

  +15° to +120°F (-10° to +50°C).

120/277

WPAK-33518-S*

 8-relay Control Panel

WPAK16-3351-S*

 16-relay Control Panel

WPAK-33018-S*

  Expansion Panel

120/347

WPAK-33318-S*

  8-relay Control Panel

WPAK16-3331-S*

 16-relay Control Panel

WPAK-33018-S*

  Expansion Panel

277/480

WPAK-33524-S*

  Four 2pole-Relay Panel

WPAK16-3352-S*

 Eight 2pole-Relay Panel

WPAK-33024-S*

  Expansion Panel

-S = Surface Cover

  -F = Flush Cover

Output 1

Output 2

Output 3

Output 4

Output 5

Output 6

Output 7

Output 8

Sensor 1
Sensor 2

Master Sw

Blue

White

White

White

Output 1

Output 2

Output 3

Output 4

Output 5

Output 6

Output 7

Output 8

1234567891

0

11

12

Sensor !
Sensor 2

Master Sw

Master Sw Blue
(Pre0connected)

Blue

White

White

White

LitePak Panel  (hinged cover open) 

n

 

Cover latch can be locked if desired. 

n  

Open cover to access control module

  or manual switching levers built into relays.

W

24VAC 

Power

Sw

2

Sw

1

Sw

5

Sw

4

Sw

3

Group

Sw

LitePak Panel (cover removed,
 controller door open)

n  

Remove cover to access line voltage circuits.

Optional Remote Switches

Connect standard Douglas switches
direct to relays for remote override.
Group switch input on controller can
switch some or all of the outputs.

Optional Remote Photo Sensor

Range: 0 to 6,500 fcandles (±5%).
Each output can have a unique setting.
If sensor not installed, use astronomic
function for dusk-to-dawn applications.

Controller Module

LCD display and membrane keypad
used to view/edit settings and schedules.
Eight outputs, each has a unique schedule.

14"

(356)

12"

(305)

4.5"

(114)

n

 

Indoor applications only.

  Surface mount Nema 1 Enclosure.

n

 Remove cover to  access 1/4"  mounting 

holes and attach to wall. 

A

B

C

D

Esc

Clr

1

2

3

4

5

6

7

8

9

0

Power

Dire ctions:

•  Bu tto n s  A ,  B ,  C  &  D   se le ct  o p tio n s  s ho w n  a t  th e  b otto m   of  th e  d isp lay.  F o llo w  p r om p ts

  w h ic h   a p pe ar   o n   th e  d is pla y  to   s et  u p   th e   u n it  an d /o r  v ie w /e d it  p ro g ra ms . 
•  Us e o n ly  to c on tr ol Do u g las R elay s. Th is u n it c an  be  set to  d o s om e o r all of th e fo llo w in g:
  -  Sta nd a rd  Tim e Sch e du les :

  O N/O FF ,  Re pea t O F F  &  F l ick-W ar n  O FF .

  - A stro n o mic  

C o ntr o l:

 Du sk-to-D aw n & Du sk-to-D awn  with  T i m e con trol .

  - Ph o to ce ll 

Co n tro l:

  D usk- to -Da wn , D usk-to-D aw n w ith T im e  co ntro l. S etpo ints for ea ch o utpu t

              ca n  be   un iqu e  to  sui t  d iffe ren t  a pp lic atio ns            (N ote:  Re qui res  W PS-5 52 7  Sen sor ).

 

-  T imed -O N  m o d e:

  A  re la y th at is swi tc hed  ON  with  a  loca l sw itch wi ll  b e au tom a ti cal ly

   sw itche d  O FF   after  a  "T i m ed -O N"  pe rio d  (a dju stab le).  T he  "T i m ed  O N "  m od e  can   be
   sch ed ule d to be  active  fo r ce rtai n pe riod s (e.g.: eve nin gs).  

•  F o r mo re  in fo rm atio n , p lea se r efe r to  "L itePa k Pa ne ls  -   Ap p lic atio n s & In str uc tion s ".

n

  All purpose panels suitable for 

controlling all types of lighting loads 
including HID ballasts and lamps.  
Each panel has an 8 output 
controller and 8 or 16 HID relays.     
If needed, use an Expansion Panel 
to increase capacity.

n

  LitePak panels are equipped with a 

controller unit that uses a self-
prompting  graphical LCD display 
and keypad. Several features are 
available including: time   
scheduling, astronomic, flick warn                   
and time-out.

n

  Optional WPS-5527K photo sensor 

permits the setting of precise 
numeric light levels for each output  
if desired. 

n

  Remote switch stations can be 

connected to permit easy user 
override. Indicating, non-indicating 
and keyed switches are available.

24V Transformer

120/277 V primary, 24V sec @ 75VA
Class 2 control transformer. 

  Loads  

8 relays

16 relays

8 or 16 Douglas 2wire HID Relays

Suitable for all types of lighting loads 
including HID.
Relays have a manual control lever built in 
and are latching.
Thus they will retain state (ON or OFF) 
even if the controller module is 
disconnected. This feature permits easy 
testing during installation and provides a 
guaranteed override provision for the 
occupant.

Output 1

Output 2
Output 3
Output 4
Output 5
Output 6

Output 7
Output 8

1234567891

0

11

12

Sensor !
Sensor 2

Master Sw

Master Sw Blue

(Pre0connected)

Blue
White

White

White

8 relays

16 relays

8-relay models

L i t e P a k

lighting controls

L i t e P a k

lighting controls

16-relay models

23"

(584)

12"

(305)

N

A

B

C

D

Esc

Clr

1

2

3

4

5

6

7

8

9

0

Power

Directions:

• Bu tto ns  A,  B,  C  & D s el ect op tion s sh own at th e  bo tto m  of th e  di spl ay .  Fo l lo w p ro mpts
  wh i ch ap pe ar o n the d is pl ay to set up  th e uni t and /o r v ie w/ed i t pro gram s.  
• Us e on ly to co ntrol  Do ug la s  Re la ys.  Thi s un i t ca n be se t to d o some  o r a ll  of th e  fol lo win g:
  -  S tand ard   T ime   S ch edu l es:

  ON/ OFF , Repe at OFF  & Fl ick -W arn  OF F.

  - Astron omi c 

Con tro l:

  Du sk-to -Da wn   &   Dus k-to -Dawn wit h Ti me con trol .

  -  P ho toce ll  Co ntrol :

  Dusk-t o-Da wn, Dusk-t o-Dawn wit h  Ti me  c ont rol .  Se tp oi nts  f or  eac h o ut put

              can  be  u niq ue  t o  sui t  di ff eren t  ap pl ica ti ons             (No te : Requ ires  WP S -5 527  S ens or).

 

- Ti med -ON mod e:

   A   re lay  t ha t  is  swi tch ed  ON wit h  a  l ocal   swit ch  wil l be au to mati ca ll y

   swit che d OF F  af te r a  "Ti med -ON" p erio d  (a dj ust abl e).  T he "Ti med ON" mod e can be
   sche dul ed t o be act i ve fo r ce rtai n  pe riods  (e. g. :  e veni ng s).   

• Fo r mo re in fo rmati on , pl ea se refer to   "Li tePa k  Pa nel s    -   Ap pl i cati on s  & I nstruc tio ns".

Reviews: