2

Interrupter (GFCI) in accordance with
Article 680-31 of the National Electrical
Code (NEC), (Section 68-204 of the
Canadian Electrical Code [CSA]) and
local codes or ordinances.  For runs
greater than 25 feet, consult your local
licensed electrical contractor.

FOR UL/NEC MODELS ONLY:
0-3596-206, 0-3597-206, 0-3598-206

Your pump is supplied with a 3-foot,
3-wire electrical cord and 3-prong
flanged, twist-lock plug.

The pump electrical cord must be
connected to a single twist lock,
grounding type receptacle that is
located a minimum of 6 feet from the
inside pool wall.

A qualified electrical contractor must
install this receptacle in accordance
with Article 680-6 of the National
Electrical Code (NEC).  A Ground
Fault Circuit Interrupter (GFCI) must
be used.  An ON/OFF switch must be
installed at the receptacle.

Use a Hubbell No. 2310 Receptacle,
20 AMP 125 Volt A.C. or an
equivalent receptacle that meets
NEMA Configuration L5-20R.

This pump is double insulated and
grounded.  Dead metal parts are not
in contact with pool water.

FOR 6FT cord MODELS ONLY:

Your pump is supplied with a   6-foot,
3-wire electrical cord and 3-pronged
plug.  The pump is double insulated
and grounded.  The pump electrical
cord must be connected to a
grounded, 3-wire, 115 VAC electrical
receptacle.  

The receptacle must be

protected by a Ground Fault Circuit
Interrupter (GFCI) in accordance
with Article 680-31 of the National
Electrical Code (NEC), (Section 68-
204 of the Canadian Electrical Code
[CSA]) and local codes or
ordinances.

  For runs greater than 6

feet, consult your local licensed
electrical contractor.

and reassembled to its original
integrity.  A permanently installed
pool is constructed in or on the
ground or in a building such that
it cannot be readily disassembled
for storage.
(For storable pools) The unit is
provided with a ground-fault
circuit-interrupter (GFCI). To test
the GFCI, push the test button.
The GFCI should interrupt power.
Push the reset button. Power
should be restored. If the GFCI
fails to operate in this manner,
the GFCI is defective. If the GFCI
interrupts power to the pump
without the test button being
pushed, a ground current is
flowing, indicating the possibility
of an electric shock. Do not use
this pump. Disconnect the pump
and have the problem corrected
by a qualified service
representative before using.

FOR UL/NEC MODELS ONLY:
0-3596-206, 0-3597-206, 0-3598-206

8.

CAUTION

 — This pump is for

use with permanently installed
pools and may also be used with
hot tubs and spas if so marked.
Do not use with storable pools.

      A permanently installed pool is

constructed in or on the ground or
in a building such that it cannot
be readily disassembled for
storage.  A storable pool is
constructed so that it may be
readily disassembled for storage
and reassembled to its original
integrity.

FOR ALL MODELS

:

9.

SAVE THESE INSTRUCTIONS.

ELECTRICAL FEATURES

FOR UL MODELS ONLY:
0-3596-200, 0-3597-200, 0-3598-200

Your pump is supplied with a 25-foot,
3-wire electrical cord and 3-pronged
plug.  The pump is double insulated
and grounded.  The pump electrical
cord must be connected to a
grounded, 3-wire, 115 VAC electrical
receptacle.  The receptacle must be
protected by a Ground Fault Circuit

IMPORTANT SAFETY

INSTRUCTIONS

FOR ALL MODELS

:

When installing and using this
electrical equipment, basic safety
precautions should always be
followed, including the following:

1.

READ AND FOLLOW ALL
INSTRUCTIONS.

2.

WARNING

 — To reduce the risk

of injury, do not permit children to
use this product unless they are
closely supervised at all times.

3.

WARNING

 — Risk of electric

shock.  Connect only to a
grounding type receptacle
protected by a Ground Fault
Circuit Interrupter (GFCI).
Contact a qualified electrician if
you cannot verify that the
receptacle is protected by a
GFCI.
(For storable pool pumps) This
product is provided with a
ground-fault circuit interrupter. If
replacement of the plug or cord is
needed, use only identical
replacement parts.
(For all permanently installed
units) Connect only to a branch
circuit protected by a ground-fault
circuit-interrupter (GFCI)

4.

Do not bury cord.  Locate cord to
minimize abuse from lawn
mowers, hedge trimmers, and
other equipment.

5.

WARNING

 — To reduce the risk

of electric shock, replace
damaged cord immediately.

6.

WARNING

 — To reduce the risk

of electric shock, do not use
extension cord to connect unit to
electric supply;  provide a
properly located outlet.

FOR UL MODELS ONLY:
0-3596-200, 0-3597-200, 0-3598-200

7.

CAUTION

 — This pump is for

use with storable pools only.  Do
not use with permanently
installed pools.  A storable pool is
constructed so that it may be
readily disassembled for storage