background image

2

“READ ALL INSTRUCTIONS”  Failure to follow these important
safety instructions and other basic safety precautions may result
in serious personal injury.

Before you begin installing your filter, refer to your pump
owners guide for very important installation and electri-
cal information related to your filter.

ELECTRICAL/BUILDING PERMIT

Local building codes may require obtaining an electrical
or building permit and may have regulations on set
backs and barriers that must be followed.

ELECTRICAL

We recommend you have a qualified electrical contrac-
tor install the electrical power supply as specified in your
pump instructions.

INSTALLED LOCATION

Position filter, pump and any other related components
a minimum of 5 feet from pool to prevent their being
used as a means to climb into the pool by young chil-
dren.  

DO NOT

 store toys, chairs, tables, containers or

other objects within 5 feet of the pool for the same
reason.

 WARNING

SEVERE ELECTRICAL SHOCK

 could result if you

install your filter and pump on a deck or above pool
water level.  They could fall into the water, causing
severe shock or electrocution.  

DO NOT

 install on a

deck or other surface at, above or slightly below the top
rail of the pool.

PROPERLY SUPPORTED

Filter, pump and any other related components should
be properly supported to prevent damage from misalign-
ment, settlement, vibration and mounted so as to
minimize the potential for the accumulation of debris and
moisture.

ACCESSIBILITY

The circulation system components should be installed
to allow accessibility for inspection, repair or replace-
ment.

DO NOT

 alter the pump electrical cord in any way or

change the plug end to any style.

DO NOT

 use an extension cord(s).  Severe electrical

shock may occur.

PREVENT SEVERE SHOCK

To prevent the risk of severe electrical shock, plug your
pump cord end into a grounding type receptacle pro-
tected by a ground fault circuit interrupter (GFCI).
Contact a qualified electrician if you cannot verify that
the receptacle is protected by a GFCI.

IMPORTANT SAFETY INSTRUCTIONS

DO NOT

 allow children to operate or play around this

product unless they are closely supervised by adults at
all times.

Replace damaged cord immediately to reduce the risk of
electrical shock.

DO NOT BURY CORD

An exposed cord may accidentally become damaged or
severed by a sharp object or shovel resulting in severe
electrical shock.  Position cord to prevent accidental
damage from lawn mowers, hedge trimmers or other
equipment.

BARE FEET/WET GROUND

This is a dangerous combination around electrical
equipment.  Always be sure the ground under your feet
and body is dry before you touch electrical equipment.
Failure to heed this warning may cause severe personal
injury or electrocution due to severe electrical shock.

 WARNING

Avoid direct water spraying with a garden hose around
electrical outlets, pump or any other electrical devices.
Severe electrical shock or electrocution may occur.

SERVICING YOUR PUMP

Always unplug your pump from the receptacle before
servicing, adjusting or repairing.

HAZARDOUS PRESSURE

Pumps, filters and other equipment/components of a
swimming pool filtration system operate under pressure.
Incorrectly installed and/or improperly tested filtration
equipment and/or components may fail resulting in injury
and/or property damage. A qualified pool professional
MUST conduct all pressure tests. This product is
intended for above-ground/on-ground swimming pool
applications only. DO NOT connect to a high pressure
system such as a municipal water main. To prevent
explosion caused by entrapped air in the filtration
system, bleed all air from the system. Confirm that ALL
filtration system component clamps, bolts and covers
have been properly tightened.

SAVE THESE INSTRUCTIONS

Summary of Contents for ECO 0-1805-180

Page 1: ...365 2034 R ECO Cartridge Filter Model 0 1805 180 Model 0 1805 240 Model 0 1805 360 Model 0 1805 480 Owner s Guide ...

Page 2: ...k of severe electrical shock plug your pump cord end into a grounding type receptacle pro tected by a ground fault circuit interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI IMPORTANT SAFETY INSTRUCTIONS DO NOT allow children to operate or play around this product unless they are closely supervised by adults at all times Replace damaged...

Page 3: ...indicator marks on the skimmer face plate the filter and pump should be installed with all connections securely tightened TOOLS REQUIRED Flat head screwdriver Crescent wrench Measuring tape Carpenters level Flat nose shovel Rags 5 16 Nutdriver optional The following tools are required for hard plumbing Hack saw File MATERIALS REQUIRED Nine 12 x 12 patio blocks All filters The following materials a...

Page 4: ...ltering stage the cartridge cleaning process will be less frequent and will allow longer time periods between cartridge cleanings 1 Loosen the pump strainer pot lid to allow air to escape Tighten lid when water begins to flow between strainer pot lid and strainer body DO NOT over tighten When possible avoid operating your filter during peak times for electricity demands in your community Check wit...

Page 5: ...er and related components LUBRICATION There are various types of lubricants available However most are intended for moving metal parts Unfortunately these lubricants will harm or degrade plastics DO NOT use petroleum based lubricants Many people consider PETROLEUM JELLY safe for babies and can be applied to anything But it will DESTROY most plastics and o rings Silicone lubri cants available at yo...

Page 6: ...old ass y 12 340 2505 1 Cartridge locator 13 1119 1065 3 Cartridge 60 sq ft 14 340 1947 1 Coupling 15 1107 2490 1 Pipe adapter assembly 16 343 1100 1 Air relief 17 308 1241 2 4mm c s O ring 18 308 1251 1 Tank O ring gasket 19 340 2642 1 Tank cover 20 1107 2489 1 Elbow return assembly 21 395 1014 1 Pressure gauge 22 387 1030 1 S S V clamp not shown 23 343 1350 1 Filter cartridge cleaner 24 340 2485...

Page 7: ...ge locator 13 1119 1065 4 Cartridge 60 sq ft 14 340 1947 1 Coupling 15 1107 2490 1 Pipe adapter assembly 16 343 1100 1 Air relief 17 308 1241 2 4mm c s O ring 18 308 1251 1 Tank O ring gasket 19 340 2642 1 Tank cover 20 1107 2489 1 Elbow return assembly 21 395 1014 1 Pressure gauge 22 387 1030 1 S S V clamp not shown 23 343 1350 1 Filter cartridge cleaner 24 340 2485 2 Union socket 25 340 2484 2 U...

Page 8: ...ld ass y 12 340 2505 1 Cartridge locator 13 1119 1924 3 Cartridge 120 sq ft 14 340 1947 1 Coupling 15 1107 2493 1 Pipe adapter assembly 16 343 1100 1 Air relief 17 308 1241 2 4mm c s O ring 18 308 1251 1 Tank O ring gasket 19 340 2642 1 Tank cover 20 1107 2489 1 Elbow return assembly 21 395 1014 1 Pressure gauge 22 387 1030 1 S S V clamp not shown 23 343 1350 1 Filter cartridge cleaner 24 340 2485...

Page 9: ...4 340 1947 1 Coupling 15 1107 2493 1 Pipe adapter assembly 16 343 1100 1 Air relief 17 308 1241 2 4mm c s O ring 18 308 1251 1 Tank O ring gasket 19 340 2642 1 Tank cover 20 1107 2489 1 Elbow return assembly 21 395 1014 1 Pressure gauge 22 387 1030 1 S S V clamp not shown 23 343 1350 1 Filter cartridge cleaner 24 340 2485 2 Union socket 25 340 2484 2 Union nut 26 340 2502 2 Union hose adapter 27 3...

Page 10: ...ed inside filter 2 Reassemble cartridges inside up 3 Pool water chemically out of filter balance 3 Chemically treat and balance pool water condition 5 Short filter cycles 1 Cartridges clogged with 1 Clean cartridges contaminants or algae 2 Clean cartridges Refer to Hard 2 Calcium crustation on cartridge Water cloth 3 Chemically treat and balance 3 Vacuuming large amounts of pool water condition se...

Reviews: