Page 4 of 12
(Figure 1)
(Figure 2)
REMOTE SHOW RECALL PANEL
Remote control of the
Rerun Rackmount
system is accomplished by use of a
Preset 10 Architectural
(model PRE10-A) panel. The remote panel provides ten show buttons and twelve indicators (Figure 1).
Multiple remote panels can be connected in a daisy chain manner to the DMX512 input on the
Rerun
Rackmount.
NOTE: Remote panels must be wired to the DMX512 Universe 1 INPUT connector on the Rerun.
The remote panel must be configured as a remote station. Remove the jumpers located at JP2 and JP4
to configure a
Preset 10 Architectural
as a remote station (Figure 2). Place the jumper over only one of
the pins at JP2 and JP4 for storage.