background image

 

12 

 

External Power Supply

The output of the S-250-12 external power  supply, can be adjusted up and down 10%.   It is recommended to keep 

the voltage at the S-Type adjusted to at least 11.5 vdc, but no more than 13.5 vdc.  By running the enclosure higher than 13.5 
vdc may cause premature fan failure.  

It is best to check and tune the voltage at the COOLDOME™  with a voltage meter at 

the time of installation, and use the adjustment screw, located on the S-250-12, to the right side of the terminal screws, to 
raise or lower the output voltage.

For all outdoor wiring, always use an outdoor rated wiring, or wiring in weather rated conduit, out from power supply, 

into the COOLDOME™ . Follow all local and applicable wiring and safety standards. 

Please keep D/C wire runs short, to reduce low voltage line drop

.  Also, the  suggested wiring gauge table is 

provided on previous page to further prevent low voltage line drop, and  to guide you in selecting the proper wire gauge for the 
dc run from the power supply to the ST-CD.  

 It is always advisable to use a  drip loop on all wiring going directly into the ST enclosure, to reduce the risk of water 

entering and damaging internal components.  All fittings and seals must be firmly tightened and sealed, before placing the ST-
CD in service.

Inside the ST-CD we have provided a convenient Screw cage clamp style terminal blocks to wire the 12 vdc positive 

(V+),  and the 12 vdc Negative (V-) terminal.  Please strip the insulation off the last 3/8

” of the wires and fasten wiring securely 

to terminal, using a small blade screwdriver to tighten the caging mechanism on the terminal blocks.  

Please be especially attentive to wire using the Proper Polarity, so as not to damage the internal components, or 

damage your camera within.

Power Supply Specifications

Input Voltage: 90-132VAC/ 176-264VAC Selected by Switch
Frequency Range: 47- 63 HZ
Input Current @ Full Load(Typ.):  4A @115VAC, 2A @230VAC
Recommended Min. Circuit Breaker for 110VAC In: 10 A (type C)
Int. Electrical. Working Temp*: -20 ~ +70C
Ext. Power Supply Output: 18A @ 12VDC up to 50C
Derate 0.5A/ deg. C over 50C

COOLDOME

™  Specifications

Current Draw by COOLDOME @ 12VDC:
Active Cooler OFF: 0.4A/ Active Cooler Peak On: 10.5A
Active Cooler On Typ.: 9.0A/ (Cam. Draw Not Incl.)
MTBF: 238.9Khrs min. MIL-HDBK-217F(25C)

COOLDOME

™  Input Power Configuration: ST-CD-12VDC

LOW VOLTAGE RUN:  Voltage Drop Table (shown on prior page)

Where we conservatively try to keep the voltage drop under  1.2 vdc over the low voltage direct current run.  These multipliers 

are approximate, and voltage drop (Vd) is maximum at full 12 amp load at 12 vdc.  This voltage drop is under fully loaded condition, when 
the cooling unit is engaged, and camera and all accessories are on.  Voltage drop will be much less,  if the current is not at full load.

Reusable Desiccant Canister

The reusable desiccant canister contains forty grams of silica gel.  This will prevent moisture 

buildup inside the COOLDOME™ .  Make sure to remove the canister from its foil envelope packaging 
before the COOLDOME™  is put to use.  

There is a small window on the canister (white circle).  Ensure that the crystals are blue.  

Occasionally, especially in humid environments, the canister may need to be serviced.  If so, the crystals in 
the window turns pink, indicating the silica gel is saturated with moisture and can be reactivated by being 
placed in an oven at 300 °F for three hours or until the crystals turn blue again.  The gel can be reactivated 
virtually an infinite number of times.

Warning!!!:

  COOLDOME Enclosure runs on 12 VDC only!  If high voltage is applied directly to COOLDOME™  

enclosure, you will damage housing, void warranty, and create electrocution hazard that can be harmful or fatal. 
Do not start wiring until you have fully read and understand these installation instructions.  

Summary of Contents for COOLDOME 12 VDC

Page 1: ...INSTALLATION GUIDE Mounting Sealing of Housing Electrical Details COOLDOME ENCLOSURE SERIES D2 COOLDOME D3 COOLDOME S TYPE COOLDOME...

Page 2: ...of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and...

Page 3: ...to eliminate any moisture dust and insect damage safety performance reliability and maintenance related issues Use of Electrical Conduit without sealing the entry ports inside wire feeds within Camer...

Page 4: ...GUIDE VENT STOPPER PLUGS for Conduit 1 Pull wires to final installed length 2 Open Vent Stop Plug and install over wire 3 Pinch Plug to compress over wire and insert into conduit feed mouth 4 Push pl...

Page 5: ...st be installed into COOLDOME prior to entering enclosure into service Active Cooler within COOLDOME lowers temperature to at or near dew point within COOLDOME so trapped air must be dried out to elim...

Page 6: ...cted and kept off while installing or Servicing Enclosure Follow All Local and Applicable Electrical Codes and Standards for Installation of Electrical components All Cable Ports wire feeds or Conduit...

Page 7: ...g Tools Drill Bits For Wall Mounting Drill and Bits for user supplied fasteners for wall mounting enclosure For Pole Mounting Strapping Banding Tools for user supplied Stainless Steel Pole Straps For...

Page 8: ...6 Low Voltage Line Drop Wire Gauge Tables See 12 VDC 24 VDC Low Voltage Wire Gage Selector Appendix Chart...

Page 9: ...7...

Page 10: ...8 Low Voltage Wire Gage Selector Charts Per Conductor Pair Per Cooler D3 COOLDOME uses Dual Coolers Requires Two Pair...

Page 11: ...e current load it is best to run two pairs individually So each 12VDC paired wiring runs load of one cooler Low Voltage 12 VDC Output Terminals Color Symbol Terminals Description Red V 9 10 11 Positiv...

Page 12: ...power and COOLDOME Voltage drop is based on fully loaded cooler engaged conditions and camera powered allowing up to 3 amps at typical ambient temperatures of 100F Inside D3 CD at rear of upper on enc...

Page 13: ...Safety Ground Front of Power Supply with terminal strip Rear of Power Supply with Input Voltage Selector Select Input Voltage before Hooking up Power Supply 110 VAC or 220 VAC Low Voltage 12 VDC Outp...

Page 14: ...ut Voltage 90 132VAC 176 264VAC Selected by Switch Frequency Range 47 63 HZ Input Current Full Load Typ 4A 115VAC 2A 230VAC Recommended Min Circuit Breaker for 110VAC In 10 A type C Int Electrical Wor...

Page 15: ...13 D2 D3 Mounting Detail...

Page 16: ...14 S Type Strong Arm Mount Wall Mounting Pattern Not to Scale...