background image

Assembly

Preparing the connection

Bear the supply cable and a free cable routing in mind. The connection cable must be led back-

wards away from the spot. It must not be laid forward past the spot across the installation hole of 

the spot. If possible, the supply cable of the spot should be laid in an empty conduit.

Aligning the dispersion angle and tilting the LED lamp

Determine the dispersion direction of the spot before installing it. When doing so, observe the later 

orientation of the spot.

The 

brilliance

 is available with lenses of three different dispersion angles: 10, 20 and 35 degrees. 

In order to optimize illumination, the LED lamp mount can be pivoted by up to 25 degrees in each 

direction. Adjustment is to be made prior to installation (see fig. 1 middle of this manual). The lamps 

are pre-set to an angle of 0 degrees. For adjusting pre-set pivot angles, a pattern is enclosed.

1.

  Slightly loosen the four fixing screws of the pressure ring underneath the spot. Do not completely

 

 

unscrew the screws and do not remove the ball from the housing.

2.

  Set the desired angle by pivoting the ball and screw tight the four screws until the pressure ring  

 

in  the  screw  area  lies  flat  against  the  housing  (a  slight  deformation  of  the  pressure  ring  is 

 

 normal).

 

During this procedure, the spot must be absolutely dry and clean. In particular, no dirt or water  

 

must enter between the housing and the ball.

3.

  Before installing the spot, check its setting.

Connecting and inserting the spot

Prior of inserting the spot, run the connection cable through the installation hole and if necessary 

the empty conduit towards the power supply. There should be a cable loop behind the spot allowing 

it to be pulled out at any time.

Connect the spot (see below) and test the installation.

Now insert the spot, while curling up the excessive connection cable into the mounting sleeve / the 

mounting space.

Squeeze the two retaining clips. Turn the luminaire, till the orientation of the luminaire is right. Slide 

the luminaire now just in the mounting hole / the mounting sleeve until the bezel of the spot rests.

Installation of other accessories

During the installation of other accessories, refer to the respective installation instructions at-

tached.

Assembly

Connection 

Attention:

 The design of the complete system and of the required power supplies must be carried 

according to the protective low voltage SELV prescriptions!

The 

brilliance

 is supplied with DC power and dimmed via a separate PWM signal (pulse width mod-

ulation). A PWM signal (S-PWM) is required for each light color. The PWM input has the following 

characteristics:

The switching point of the luminaire between on and off for the PWM level is not defined: Ideally it 

should be worked with a switching impulse between ground and open contact or optionally with an 

impulse between ground and operating voltage. A PWM signal differing from the operating voltage 

is not allowed.

Free cabling

The connect is made according to the assignment tables. The connection must be carried out ac-

cording to the required IP classification.

Attention: 

In case the luminaire is used without the dimming function, the PWM line (wire for the 

PWM signal) must be connected to ground (-). Otherwise the LED remains off.

Connection diagram of the brilliance white / monochromatic / with / without dimmer

See respective drawings in the middle of this manual (p. 14).

22

23

en

en

PWM line connected to ground (-)

LED on

PWM line open

LED off

PWM line connected to operating voltage (+)

LED off

PWM frequency = 0 to 1,000 H

brilliance white / monochromatic
Wire color

Assignment

red

+ 24 Volts

blue

S-PWM

black

ground (-)

brilliance RGB
Wire color

Assignment

white

+ 12 Volts

red

red S-PWM

green

green S-PWM

blue

blue S-PWM

black

ground (-)

Summary of Contents for brilliance

Page 1: ...dot spot brilliance de Bedienungsanleitung en Operator s Manual...

Page 2: ...g mit Die Nichtbeachtung dieser Anleitung kann zu Gefahren f r Personen und Sch den an Gegenst nden f hren F r Personen und Sachsch den die aufgrund der Nichtbeachtung dieser Gebrauchsanleitung entste...

Page 3: ...tzlichen Blend schutz 30010 Modelvarianten HC mit eingebautem Wabenblend schutz 30110 10 Leuchtintensit t Lichtfarben Bestell nummer Lumen nur zur allgemeinen Information Betriebsspannung warmwei 2700...

Page 4: ...lareffekt bis zur Elektronik in der Leuchte vordringen und diese zerst ren Montage Vorbereitung Packen Sie den gesamten Lieferumfang aus und berpr fen Sie den Inhalt je nach Ausstattung auf Vollst ndi...

Page 5: ...zeit das Herausziehen des Strahlers aus dem Montageloch erm glicht Schlie en Sie die Leuchte an siehe unten und testen Sie die Installation Nun die Leuchte einsetzen dabei das bersch ssige Anschlusska...

Page 6: ...sch tzt ist der dauerhaft anormale Betrieb zu vermeiden Die W rmeabfuhr von der LED darf nicht behindert werden Decken Sie den Strahler daher nicht ab Vermeiden Sie den Betrieb des Strahlers bei direk...

Page 7: ...t Netzteil austauschen Leuchte defekt Leuchte einschicken Strahler blinkt flackert oder schaltet sich nach kurzer Betriebszeit ab das Netzteil wird sehr hei Netzteil berlastet Netzteil mit h herer Lei...

Page 8: ...ck blau blue DIM Adernfarben wire colors rot red schwarz black blau blue DIM F1d3 Zeichnung zum Ausrichten des Abstrahlwinkels und Schwenken der LED Leuchte Drawing for aligning the dispersion angle a...

Page 9: ...s may cause danger to persons and damage to property dot spot will not assume any liability for damage to persons and property resulting from failure to follow this operator s manual Scope of delivery...

Page 10: ...5 m with M12 plug M12 housing connector Protection class of the spot IP 68 up to 1 m water depth IP 67 for M12 plug system mechanical load capacity 3 t IK10 Temperature range 25 C 45 C Storage Temper...

Page 11: ...nd destroy the electronics of the spot Assembly Preparation Depending on the configuration unpack all the parts included in the scope of delivery and check them for completeness and intactness Dispose...

Page 12: ...lation Now insert the spot while curling up the excessive connection cable into the mounting sleeve the mounting space Squeeze the two retaining clips Turn the luminaire till the orientation of the lu...

Page 13: ...ROTECT system that protects the luminary against thermal damage a permanent abnormal operation should be avoided The heat dissipation of the LED must not be hindered Therefore do not cover the spot Av...

Page 14: ...ic control gear for LED modules IEC 61347 2 13 In case of damage resulting from operation with unsuitable electronic ballasts power supplies or other power sources no guarantee claims can be made Thes...

Page 15: ...ice dot spot de www dot spot de Details zum Produkt Lichtverteilungskurven Gebrauchsanleitung als PDF EG Konformit tserkl rung als PDF Zubeh r Weitere technische Unterlagen wie z B Planungshilfen Vide...

Reviews: