Dosy TC-4002-PSW Instruction Manual Download Page 3

1

2

3

4

5

6

7

8

SWR Set

1. Turn Mode Selector Switch (#5 Fig. 1) to SWR-SET Position.
2. Turn SWR RF Level Control (#8 Fig. 1) to Min.
3. Key transmitter and turn SWR RF Level Control clockwise
    (#8 Fig. 1) to give a full scale meter reading to Set Line on
    the SWR Meter.
4. With Transmitter keyed, switch Mode Selector Switch (#5 
    Fig. 1) to the SWR position and read SWR ratio directly on
    SWR Scale.

NOTE: The SWR Functions need to be performed on each
wattage range to prevent possible damage to the meter
movements.

Installation Instructions

The test center can be installed at any point in your transmitter line.

Transmitter

RG/58BU

Input

Vert.

AUX 3rd ANT or

Dummy Load

Horz.

IMPORTANT

On the DOSY TC-4002-PSW, be VERY careful if only one antenna is used. Before 

the transmitter is keyed, make sure the antenna switch (#1 Fig. 1) is in the

proper position for desired antenna. If this switch is in one of the other positions

and the transmitter sees an open load, the watt meter diodes may be

damaged and the transmitter may also be damaged.

Operating Instructions

Watts

The TC-4002-PSW Test Center will indicate the power output (in
watts) of your equipment at the point in the transmission line
where you have installed the test center.  To measure any
power from 1 to 2000 watts, just set the Mode Selector Switch
(#5 FIG. 1) to the appropriate range: 20, 200, 2000 watts. 
If wattage to measure is larger than 2000 watts, the 2000/
4000 switch (#3 Fig. 1) must be switched to 4000. When
returning back to the 2000 watt scale, you must return the
switch (#3 Fig. 1) back to the 2000 watt setting.

NOTE:  If power output is uncertain, use the highest range
and work down until the range is appropriate to prevent
possible damage to the meter movement.

DOSY Test
       Center

RMS/Peak Watts

The RMS/PEAK mode switch (#2 Fig. 1) permits the selection
of either RMS or Peak Watt reading when measuring watts. 
In the RMS position, there will be steady or very little movement
of the watt meter needle.  When the RMS/Peak Mode Switch 
(#2 Fig. 1) is in Peak position, watt meter will indicate peak
power output.

Antenna Selector Switch operation 

(#1 Fig. 1)

1. VERT position for a VERT antenna or GR plane.

2. HORZ position for a HORZ antenna or BEAMS.

3. AUX position for a third antenna or a dummy load.

4. VERT/HORZ position ties in both VERT and HORZ antennas to the transmitter

    input at the same time.  Make sure (if only one antenna is used) that the

    antenna selector switch is in the same position as the antenna cable on

    the back of the test unit.

Power Plug

Headphone and Dial Lite

This DOSY meter is equipped with a head phone jack and meter panel

lights. For these features to work this unit must be plugged into a 120-volt

outlet with the supplied power adapter.  The power adapter cable must be

plugged into the power jack on the back of the test center.  Position

the toggle switch (#6 Fig. 1) to the ON position to turn on the lights.

1. Antenna Selector Switch
2. RMS/PEAK Mode Switch
3. 2000/4000 Watt Range Switch
4. SET/MOD Switch
5. Mode Selector Switch
6. Ear-phone jack
7. SSB/AM Mode Switch
8. RF Level Control Modulation
    and SWR for Ear-Phone
9. Lite Switch

Figure 1