background image

Installation Instructions

The test center can be installed at any point in
your transmitter line.

Transmitter

DOSY Test Center

RG/58BU

Input

Antenna

Operating Instructions

Watts

The PM-1000/PM-2001 Test Center will indicate the power 
output (in watts) of your equipment at the point in the 
transmission line where you have installed the test center.  To 
measure any power from 1 to 1000 watts (2000 watts on
PM-2001), just set the power range selector switch (#3 Fig. 1) 
to the appropriate range - 30, 100, 1000 (or 20, 200, 2000 on
PM-2001) watts. Key the transmitter and read the wattage on 
the corresponding scale.

NOTE:  If power output is uncertain, use the highest range
and work down until the range is appropriate to prevent
possible damage to the meter movement.

SWR Set

A.M. Modulation Check

1. Turn Mode Selector switch (#3 Fig. 1) to the SWR SET position
2. Turn RF Level Control (#1 Fig. 1) to MIN
3. Key Transmitter and turn RF Level Control (#3 Fig. 1) to give

a full scale meter reading to SWR SET on meter scale.

4. With Transmitter keyed, switch Mode Selector Switch

(#3 Fig.1) to SWR position and read SWR ratio directly on
SWR Scale.

NOTE: 

The SWR Functions need to be performed on each wattage range

to prevent possible damage to the meter movements.

1. Turn Mode Selector Switch (#3 Fig. 1) to MOD position
2. Switch MOD/SET rocker (#2 Fig. 1) to SET
2. Turn RF Level Control (#1 Fig. 1) to MIN
3. Key Transmitter and turn MOD RF Level Control (#1 Fig. 1)

to read full scale to MOD SET on meter scale

4. With transmitter keyed, switch MOD/SET rocker (#2 Fig. 1)

to MOD position and talk or steadily whistle into
microphone.  Read modulation percentage on AM MOD
scale

5. DO NOT CHECK MODULATION WITH HIGH POWER

NOTE: 

A.M. modulation check functions must be performed on each

wattage range, to prevent possible damage to the meter movements.

General Notation

On Grounded Grid amplifiers, we do not recommend checking modulation

at higher powers.  Grounded Grid amplifiers will not be able to output 100%

modulation in the A.M. mode, however, the feed through power prevents

the grounded grid from being fully modulated.  This is the reason A.M. 

modulation should be checked at the transmitter, or with the Linear

Amplifier in standby position.

Peak Watts

The PM-1000/PM-2001 watt meter will indicate peak watts 
when transmitter is modulated.

Figure 1

2. Rocker Switch for Modulation

and set

3. Mode Selector

Switch

1. RF Level &

Modulation Set

Rely only on high-grade cb radios & components offered on our virtual shelves.