21
20
The bottom status line shows battery capacity, logger mode and
alarm status. The green LED flashes every 30 seconds during
recording. The red LED is used to display limit alarms or status
messages (battery change ...etc.). The logger also has an internal
buzzer that supports the user interface.
This product is exclusively intended for the field of application
described above.It should only be used as described within these
instructions.Unauthorized repairs, modifications or changes to the
product are prohibited and void any warranty!
5. How to use device
5.1 Device description
Fig. A
(see page 2)
1. USB cover
2. USB-connector
3. LCD display see Fig. B
4. LED: green/red
5. Sensor compartment
(position of the sensor)
6. Battery case
7. Mode button,
8. Start / Stop button
9. lockable wall holder
If the display has been deactivated (display off via Software LogConnect),
the battery symbol and the symbol for recording (►) or configuration (II) are
still active in Line 4 (status line).
Fig. B
(see page 2)
1. Units of measurement line 1
2. Measurement line 1
3. Units of measurement line 2
4. Measurement line 2
5. Line3 for indication and
extrema measurements
AVG = average value,
Min = minimum value,
Max = maximum value
6. Line4 status line (from left to
right):
5.2 Start-up device
ATTENTION!
Please observe our battery recommendation strictly.
Use only the battery type LS 14250 3.6 volt of manufacturer SAFT,
respectively only batteries authorized by the manufacturer.
For operation take out the instrument from the pa-
ckaging, remove the display foil. The logger is already
preset and ready for start. It can be used immediately
without any software!
By pressing any button or moving the instrument before
first operation the instrument displays FS (factory set
-
ting) for 2 seconds, afterwards measurements are displayed for
2 minutes. Then the instrument display switch off. Repeated key hit
or movement reactivates the display.
5.2.1 Factory presets
Note the following default settings of the data logger before first
use. By using the LogConnect* software, the setting parameter can
easily be changed:
Recording Interval: 5 min. LOG210/ LOG220,
15 min. LOG200
Measuring interval: During recording the measurement interval and
recording interval is the same! If the logger has
been not started( NOT RECORDING) the measuring
interval is every 6 seconds for 15 minutes, after-
wards the measuring interval is every 15 minutes
for 24 hours, afterwards the measuring interval is
once per hour. If you press any button or move the
device it will start again to measure each 6 seconds.
Start possible by:
Key press
Stop possible by:
USB connect
Alarm: off
Alarm delay:
0 s
Show measurements on display: on
Power-Save mode for display: on
Battery indication,
USB-connection indication,
Data logger is recording,
Data logger has been
configurated by LogConnect
and is waiting for action,
Data logger has been
stopped and
OK, (without
► Symbol)
Data logger has been
stopped and X NOT OK
(e.g. Alarm level reached
(without ► Symbol)