Tip replacement 

Note: Tip replacement or cleaning should be done only when the iron is at room temperature or below. The tip can 

be changed or replaced simply by unscrewing the knurled nut barrel assembly. The station must be switched off 

and allowed to cool before and during this operation, as damage may result if the system is left on without the tip 

inserted, after removing tip, remove any oxide dust that may have formed in the tip retaining area of the barrel. Be 

careful  to  avoid  getting  dust  in  your  eyes.  Care  should  be  taken  not  to  over  tighten  as  this  would  damage  the 

element. 

 

General cleaning 

The outer case of the iron or station  may be cleaned with a damp cloth using small amounts of liquid detergent 

Never submerse the unit in liquid or allow any liquid to enter the housing. Never use solvent to clean the case.   

 

Warning   

 

The appliance is not a toy, and must be kept out of children’s reach. 

 

Before  cleaning  the  appliance  or  changing  the  filter,  always  unplug  it.  Unscrewing  the  housing  is  not 

permitted. 

 

This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced  physical,  sensory  or 

mental  capabilities,  or  lack  of  experience  and  knowledge,  unless  they  have  been  given  supervision  or 

instruction concerning use of the appliance by a person responsible for their safety. 

 

Children should be supervised to ensure that they do not play with the appliance. 

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard. 

 

 

 

Note:  This  instruction  is  also  available  to  download  from  the  distributor’s  website: 
www.doss.com.au.

 

 