7
FAULTS
Any operation faults will be displayed after 90 seconds and will be presented on the display with the
following codes:
1
The thermostat has short-circuited or is not correctly connected to the control unit:
E6
2
The compressor is blocked:
E3
3
The ventilator is sending the control unit a value which exceeds 0.6A:
E2
4
The cooling system holds too much gas and the compressor is not able to operate
at the minimum number of revolutions/rpm:
E4
5
The ambient temperature is too high:
E5
6
E1
REPLENISHMENT
Avoid placing hot food in the refrigerator. Place the products so that they do not knock against each other
or break when the vehicle is in motion.
MAINTENANCE
Caution
Before carrying out any maintenance operations on the refrigerator, disconnect the power cable
from the plug.
CLEANING
Regularly clean the inside of the refrigerator using baking soda dissolved in warm water.
Do not, in any case, use abrasive products, detergents or soaps; after washing, rinse with clean water and
carefully dry.
Where the refrigerator is not being used, thoroughly clean and dry the inside in order to avoid the formation
of mould or foul odours.
HELPFUL ADVICE
Where the refrigerator does not function or functions incorrectly, before contacting one of our technical
assistance centres, ensure that:
a) there is a power supply.
b) the voltage complies with that indicated on the plate.
c) the connections and poles are correct.
d) the ventilation grids are not obstructed.
e) the fridge unit is not placed near to a heat source.
f) the power supply fuse is not interrupted.
Caution
authorised by the Manufacturer.
Indel B will not assume any responsibility in the instance where the instructions in this present
manual are not fully respected.