background image

7

FAULTS

Any operation faults will be displayed after 90 seconds and will be presented on the display with the 
following codes:

1

The thermostat has short-circuited or is not correctly connected to the control unit:

E6 

2

The compressor is blocked: 

E3

3

The ventilator is sending the control unit a value which exceeds 0.6A:

E2

4

The cooling system holds too much gas and the compressor is not able to operate 

at the minimum number of revolutions/rpm:

E4

5

The ambient temperature is too high:

E5

6

E1

REPLENISHMENT 

Avoid placing hot food in the refrigerator. Place the products so that they do not knock against each other 

or break when the vehicle is in motion.

MAINTENANCE

Caution

Before carrying out any maintenance operations on the refrigerator, disconnect the power cable 

from the plug.

CLEANING

Regularly clean the inside of the refrigerator using baking soda dissolved in warm water.

Do not, in any case, use abrasive products, detergents or soaps; after washing, rinse with clean water and 

carefully dry.

Where the refrigerator is not being used, thoroughly clean and dry the inside in order to avoid the formation 

of mould or foul odours.

HELPFUL ADVICE

Where the refrigerator does not function or functions incorrectly, before contacting one of our technical 

assistance centres, ensure that:

a) there is a power supply.

b) the voltage complies with that indicated on the plate.

c) the connections and poles are correct.

d) the ventilation grids are not obstructed.

e) the fridge unit is not placed near to a heat source.

f) the power supply fuse is not interrupted.

Caution

authorised by the Manufacturer.
Indel B will not assume any responsibility in the instance where the instructions in this present 

manual are not fully respected.

Summary of Contents for PF18 YCD15A

Page 1: ...PF18 DOSS 18L PORTABLE FRIDGE DC12V 24V COMPRESSOR REFRIGERATOR ...

Page 2: ...rectly from the cigarette lighter found in the passenger compartment of the vehicle itself They can be used both as refrigerators and freezers They are made up of a plastic external structure plastic internal compartment access door internal insulated compartment for holding products compressor cooling unit control panel power cable They are also equipped with a strap so that they can be easily tr...

Page 3: ... 35 W 35 W Supply voltage DC 12 24 V DC 12 24 V Electrical power within the shell Fuse 10A Fuse 10A Temperature setting 10 to 18 C 10 to 18 C Cooling system Danfoss BD Micro Bd1 4F Danfoss BD Micro Bd1 4F Refrigerant gas R134a CFC Free R134a CFC Free Insulation CFC Free PU Foam CFC Free PU Foam H L P Fitting kit Optional Optional ...

Page 4: ...thin the refrigerator Do not place hot products within the refrigerator ATTACHMENT O F THE RE F RIGERATOR IN T H E VE H ICLE includes relevant strap and brackets supplied separately as an option The refrigerator is equipped with relative plug which must be connected to the cigarette lighter outlet In the instance where the above mentioned cable is not used and the supply comes directly from the ve...

Page 5: ...crease or scroll menu key 5 Temperature increase or scroll menu key 1 2 3 4 5 To increase the temperature of the cooling compartment press key 5 until the desired value appears on the display To decrease the temperature of the cooling compartment press key 4 until the desired value appears on the display ...

Page 6: ...s 2 4 5 at the same time for a few moments To scroll through the various functions within the menu use keys 4 and 5 to change the parameters of the 5 The new value will be saved If no keys are pressed you will automatically exit the menu mode BATTERY PROTECTION LEVEL It is possible to set three different battery protection threshold levels Battery protection Display 12V 24V MIN 1 Bar 9 6 21 3 MED ...

Page 7: ...odifying the preset OFF SET values With temperatures greater than 6 C set the value to OF1 which will provide a maximum difference of 2 C between the compartment temperature and the temperature on the display With temperatures between 7 C and 12 C set the value to OF2 which will provide a maximum difference of 4 C between the compartment temperature and the temperature on the display With temperat...

Page 8: ...he power cable from the plug CLEANING Regularly clean the inside of the refrigerator using baking soda dissolved in warm water Do not in any case use abrasive products detergents or soaps after washing rinse with clean water and carefully dry Where the refrigerator is not being used thoroughly clean and dry the inside in order to avoid the formation of mould or foul odours HELPFUL ADVICE Where the...

Reviews: