Reinstall the check valve nut.
Set the stem aside and pick
up the blue body. Remove and
replace the
Plunger Seal
(
Part #: JDI200
)
,
by pinching
it and rolling out of the plunger
or using a small flat blade
screwdriver.
Be careful not to damage the
tip of the plunger.
Carefully insert the plunger
inside the top of the stem in a
vertical motion to avoid bending
the plunger.
Align the notches in the lower
part of the blue body with the
teeth on the top of the injection
stem assembly.
20
19
21
19