WARNING!
Unsuitable tools in explosive areas
Tools that do not have Ex approval can generate
sparks and cause a fire or an explosion in Ex
zones. It can cause serious injuries or death.
– If possible, carry out cleaning and mainte-
nance work outside the Ex zones.
– For work within the Ex zone, use tools with
the corresponding Ex labeling.
6.2
Preparing for commissioning
Personnel:
Mechanic
Protective equipment:
Protective gloves
Anti-Static Safety Boots
Carry out the following checks for the operation:
Check grounding connection of the pump.
Ambient temperature
Relative humidity
Compressed air connection is flexible and con-
ductive.
Connections of the suction and pressure line
are designed to be conductive.
The connection of the suction and pressure line
must be flexible to equalize vibrations of the
pump. Connections must not be made using
tubes and must be compatible with the material
to be pumped.
Connected media lines and connections are
sealed.
Check all screw connections with a torque
wrench.
6.3
Setting operating parameters
Personnel:
Mechanic
Protective equipment:
Protective gloves
Anti-Static Safety Boots
Input pressures of the media supplied via the
tube system are within the required ranges
7
Operation
7.1
Safety recommendations
WARNING!
Hot surfaces
In operation, the surfaces of the product can heat
intensely. Contact can cause burn injuries.
– Wear protective hand gloves.
WARNING!
Danger from noise
Disconnecting pressurized pneumatic lines cre-
ates loud noises. This might damage the hearing.
Before carrying out any work:
– Depressurize pneumatic lines. Secure against
reconnection.
– Wear ear protection.
WARNING!
Danger of explosion due to sources of igni-
tion in an explosive atmosphere.
Sparks, open flames and hot surfaces can cause
explosions in explosive atmospheres. Serious
injury and death could be the consequence.
– Do not use any sources of ignition and no
open light in the work area.
– Ensure that the forced ventilation is opera-
tional.
– Do not smoke.
– Ground Pump.
– Wear suitable protective equipment.
WARNING!
Danger of fire and explosion
Flammable coating materials and their deter-
gents and cleaning agents can cause a fire or an
explosion.
– Ensure that the flashpoint of the fluid is at
least 15 K above the ambient temperature.
– Note explosion group of the fluid.
– Follow the safety data sheet.
– Ensure that forced ventilation and fire protec-
tion equipment are in operation.
– Do not use sources of ignition and open light.
– Do not smoke.
– Check grounding.
Operation
01/2020
EcoPump AD - MPU00013EN