9.3.3 Replace material flow control
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Anti-Static Safety Boots
Requirements:
Disassembly
Fig. 34: Disassemble adjusting screw
1. Unscrew and remove the adjusting screw
(1) with the supplied open-end wrench
(included in the tool kit).
Fig. 35: Replace O-ring of the adjusting
screw
2. Replace O-ring (2).
Assembly
3. Lightly grease new O-ring (2).
4. Insert and tighten adjusting screw (1).
Faults
11/2019
EcoGun AS MAN DC - MSG00023EN