NOTICE!
Material damage due to dried material
residues
If material residues dry in the product, that
can harm components.
– Rinse product immediately after each
use.
6.2
General notes
1. Perform the following checks during oper-
ation:
Check O-rings for correct seating and
tightness.
Check air car for cleanliness.
Check nozzle for cleanliness.
6.3
Selecting air cap
The spray gun is suitable for different appli-
cations. The selection of the air cap deter-
mines the area of application.
Air cap HN 400
The air cap HN 400 is used for small and
narrow applications:
Spray pattern width 30 - 170mm
Flow rate 50 - 160mL/min
Air cap HN 600
The air cap HN 600 is the standard type. It
achieves a great degree of efficiency with
fine atomizing:
Spray pattern width 90 - 300mm
Flow rate 150 - 280mL/min
Air cap HN 800
The air cap HN 800 is a highly atomizing
model for applications with higher viscosity
or higher flow rates:
Spray pattern width 230 - 350mm
Flow rate 230 - 400mL/min
6.4
Changing the air cap
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Anti-Static Safety Boots
Requirements:
The electrostatic controller is switched
off.
Remove air cap
Fig. 19: Ground electrode
1. Discharge electrode (1) using a
grounding rod (2). In this, pull the trigger
completely.
Operation
11/2019
EcoGun AS MAN DC - MSG00023EN
14/56