19
with the alarm receiver according to the programmed order in the call sequence until the
alarm is acknowledged, or the maximum number of call attempts is reached.
“With acknowledgement” means that the receiver confirms that the alarm is received, this is
made with the “4” key if the receiver is a phone or if the receiver is an ARC by sending an
acknowledgement message to Doro Eliza.
If the receiver is a phone and the TAP-2 protocol (GSM) is used at e.g. neighbor or relative,
the Doro Eliza identifies itself with caller-ID. When an alarm is received at an ARC the
information (alarm-ID and alarm type) is sent digitally to the receiver.
If the alarm is a so-called speech connected alarm e.g. emergency alarm, there is possibility
to establish a two-way speech connection. If the alarm is a so-called technical or an
automatic generated alarm, e.g. low battery information there will not be any speech
connection.
Disconnection of an alarm is made with the
“0” key if the receiver is a telephone or by a
disconnection command from an ARC. Doro Eliza automatically disconnects the call after the
programmed connection time has elapsed (default set to 10 minutes), this time can be
extended with the
“4” key on the telephone or by a keep alive command from the ARC.
Note! During the powering up of Eliza the cellular indicator is lit.
This indicates that the Eliza is in a process of finding a data network (Cellular and/or IP)
therefore no alarm can be sent.
6.5 Function Monitoring
6.5.1 Test alarm
This is used to monitor the Doro Eliza
’s functionality and that the connection works correctly.
If the test alarm function is activated a silent alarm will be sent according to the call sequence
for alarm type 26. The time interval for test alarms can be set between 1 and 999 hours.
The Function monitoring can also be formatted according to the SCAIP specification
(Ping/heartbeat). Ensure that the selected ARC can handle this format before enabling the
functionality.
Disabled=0 (off)
Value: 1-999 hours, Default: 0 hours