background image

14

www.doro.com/care

Doro CareIP

®

10. 

General information

• 

If Broadband/network connection is used the unit should always be connected to 

the network as near the router (or Ethernet connection) as possible.

• 

Verification of GSM coverage should always be done as a part of installation.

• 

In order for an alarm to be sent, at least one alarm receiver/response centre needs 

to be programmed.

•  The carephone must not come into contact with water or any other liquid.
• 

Used batteries shall be disposed of in an environmentally-responsible manner.

• 

If the Doro CareIP® Mobile is supposed to be connected to a mobile network it 

need to be equipped with a 2G enabled Mini-SIM (2FF) and having an appropriate 

mobile subscription including voice and data.

Cleaning

The carephone and Elliot should be cleaned using a slightly damp cloth. Do not use 

solvents when cleaning.

Note!

 By ordering a complete housing set you can upgrade your used Elliot to look as 

brand new.

Reinstatement

If the Doro CareIP® Mobile is reinstated at a new user, it shall be reset to default 

settings and re-programmed according to the data and requirements of the new user.

11. Maintenance

Replace the battery

Battery should be replaced within three years, or a.s.a.p after battery alarm.

Replace the radio trigger battery

To replace Elliot's battery, please refer to the service manual or contact your supplier.

 CAUTION

Battery replacement may be performed only by authorised persons in 

accordance with the instructions in service manual.

Summary of Contents for 1-9300-210)

Page 1: ...Doro CareIP Mobile User Guide English...

Page 2: ...vers on the backside may be opened only by authorised persons in accordance with the instructions in the service manual Battery replacement may be performed only by authorised persons in accordance wi...

Page 3: ...as especially radio communications Contact your supplier immediately in case of any suspected malfunction Users should pay particular attention to the risk of disruption from products which communicat...

Page 4: ...nected the Ethernet link supervision can be disabled by configuration Slow flashing Registration to SIP server failed 4 STATUS RED GREEN Off Normal operation Steady red light No connection to GSM netw...

Page 5: ...tputs and inputs 6 Ethernet port Connection for Ethernet cable from broadband network 7 DC in Connection for power supply 7 5 VDC 8 Power switch Turns Doro CareIP Mobile on and off 9 Antenna connector...

Page 6: ...The assistance alarm can be activated 1 by pressing the button on a radio trigger 2 by pressing the red button on the Doro CareIP Mobile 3 by pulling the pull cord only available when Doro CareIP Mobi...

Page 7: ...rew the safety screw for the SIM card compartment cover Remove the compartment cover Install the SIM card according to picture note the markings Mount the cover and the safety screw for the SIM card c...

Page 8: ...1 to the wall socket and the power supply lead to the DC input socket 2 Connect the network cable 2 from the broadband network to the Ethernet socket on Doro CareIP Mobile Turn the power switch to the...

Page 9: ...cy 2 a Mobile connection to GSM GPRS Voice IP alarm protocol and additional data b IP on Ethernet VoIP IP social alarm protocol and additional data 3 IP connection through GPRS 4 Voice connection thro...

Page 10: ...radio transmitters Hold down the green button for approximately four seconds until the unit emits a beep release the button The indicator light On flashes green Press the radio trigger Once the Doro C...

Page 11: ...ed to get at least strength 15 for good communication If this can t be achieved try to move the unit in different locations in the residence until approved value are fulfilled Note If accepted value c...

Page 12: ...Elliot by indicator light change from red to green If Elliot doesn t get any confirmation the alarm is repeated Elliot has two programmable buttons Elliot can be worn using a wristband neckband or po...

Page 13: ...on 1 Indicator light 2 Alarm button 3 Function button Wristband attachment 1 Neckband attachment 2 Cover plate Easy press concept EPC accessory The Doro Care Easy Press Concept EPC accessories makes i...

Page 14: ...abled Mini SIM 2FF and having an appropriate mobile subscription including voice and data Cleaning The carephone and Elliot should be cleaned using a slightly damp cloth Do not use solvents when clean...

Page 15: ...radio equipment 1 If the unit is used with optional Power over Ethernet PoE it is important to equip the PoE injector with a suitable battery back up UPS of desired capacity since the internal batter...

Page 16: ...ht incl wristband 22 g Battery 3V lithium battery CR2430 Use only GP model GPCR2430 Battery life Up to five years Water resistance Complies with IP67 Radio frequency band 869 2 869 25 MHz Radio freque...

Page 17: ...at is connected directly or via a recycling system to Doro Care or to your distributor For detailed instructions please check with your distributor or visit our website www doro com Note The WEEE info...

Page 18: ......

Page 19: ......

Page 20: ...Doro CareIP Mobile English Manual_Doro_CareIP_Mobile_en_v2 3 2017 Doro Care All rights reserved...

Reviews: