Dorner 70-40 Safety, Setup, Operation & Maintenance Manual Download Page 2

70–40 and 70–41 Emergency Stop Kit Setup, Operation & Maintenance Manual

851-462 Rev. B

2

Dorner Mfg. Corp.

The safety alert symbol, black triangle with white
exclamation, is used to alert you to potential
personal injury hazards.

Ç

Ç

Ç

Climbing, sitting, walking or
riding on conveyor will
cause severe injury.

KEEP OFF CONVEYORS.

DANGER

Ç

DANGER

DO NOT OPERATE
CONVEYORS IN AN
EXPLOSIVE ENVIRONMENT.

Controller must be properly grounded. Failure to
properly ground controller may cause injury to
personnel.

Ç

Ç

Ç

Hazardous voltage will
cause severe injury or
death.

LOCKOUT POWER BEFORE
wiring.

DANGER

Ç

Exposed moving parts can
cause severe injury.

DO NOT ATTEMPT
ADJUSTMENTS WITH
CONVEYOR RUNNING.

Ç

Dorner cannot control the
physical installation and
application of conveyors.
Taking protective measures
is the responsibility of the
user.

When conveyors are used in
conjunction with other
equipment or as part of a
multiple conveyor system,
CHECK FOR POTENTIAL
PINCH POINTS and other
mechanical hazards before
system start-up.

Introduction

IMPORTANT:

 Some illustrations may show

guards removed. Do NOT operate equipment with-
out guards.

Upon receipt of shipment:

D

Compare shipment with packing slip. Contact factory
regarding discrepancies.

D

Inspect packages for shipping damage. Contact carrier
regarding damage.

D

Accessories may be shipped loose. See accessory in-
structions for installation.

Dorner conveyors are covered by the following patent
numbers: 5131529, 5156260, 5156261, 5174435,
5203447, 5265714, 5875883, and corresponding pat-
ents and patent applications in other countries.

Dorner’s Limited Warranty applies.

Dorner reserves the right to make changes at any time
without notice or obligation.

Warnings – General Safety

Summary of Contents for 70-40

Page 1: ...cal Mounting to 2100 2200 3100 Conveyor 3 Vertical Mounting to 6100 Conveyor 3 Horizontal Mounting to 2100 2200 3100 Conveyor 4 Horizontal Mounting to 6100 Conveyor 4 Vertical Mounting to Aluminum Stand Leg 4 Horizontal Mounting to Aluminum Stand Leg 5 Vertical Mounting to Steel Stand Leg 5 Horizontal Mounting to Steel Stand Leg 5 Cable Routing 6 Service Parts 7 Return Policy 8 ...

Page 2: ...of conveyors Taking protective measures is the responsibility of the user When conveyors are used in conjunction with other equipment or as part of a multiple conveyor system CHECK FOR POTENTIAL PINCH POINTS and other mechanical hazards before system start up Introduction IMPORTANT Some illustrations may show guards removed Do NOT operate equipment with out guards Upon receipt of shipment D Compar...

Page 3: ...ap Screw 2x F M5 x 6 mm Socket Head Cap Screw 4x G Pushbutton Box 1x H M6 x 10 mm Button Head Screw 2x I Zip Tie Mount 2x J Zip Tie 2x K 4 mm Hex Key Wrench 1x L T slot Cover Strip 5x M M6 Spring Nut 2x N 6100 Mounting Clip 2x Vertical Mounting to 2100 2200 3100 Conveyor NOTE For shipping T bars A Mounting Plate B Mounting Brackets D and Pushbutton Box G are pre assembled Detach T bars before proc...

Page 4: ...Mounting to 6100 Conveyor NOTE For shipping T bars A Mounting Plate B Mounting Brackets D and Pushbutton Box G are pre assembled Detach all before proceeding 1 Install mounting clips N of Figure 7 on conveyor Figure 7 N 2 Attach Pushbutton Box G of Figure 8 to mounting plate B with screws E 3 Attach Pushbutton Box assembly G of Figure 8 with screws C Figure 8 C G B C E Vertical Mounting to Aluminu...

Page 5: ...shipping T bars A Mounting Plate B Mounting Brackets D and Pushbutton Box G are pre assembled Detach T bars and mounting plate before proceeding 1 Install two Spring Nuts N of Figure 11 into Leg slot Figure 11 B C E G N 2 Attach mounting plate B to Spring Nuts N with screws C 3 Attach Pushbutton Box assembly G to mounting plate B with screws E Horizontal Mounting to Steel Stand Leg NOTE For shippi...

Page 6: ...iring cable in the conveyor T slot channel use several short lengths of T slot Cover Strips M Figure 13 Or to completely contain a long run of cable purchase T slot Cover Strip 645656P at length required Figure 13 M 3 To route Cable over a previously mounted compo nent or to anchor the Cable use the Zip Tie Mounts I of Figure 14 and Single Drop in T bars A Secure each Zip Tie Mount with M6 screw H...

Page 7: ... Description 1 830 142 830 141 Push Button Illuminated Push Button Non illuminated 2 699727 Enclosure 3 830 190 Power Module For Illuminated Only 4 830 145 830 146 Contact Block for Illuminated only Contact Block for Both Models 5 805 655 Relay 6 805 053 Power Cord 7 805 805 Motor Cord Figure 16 3 5 6 2 1 4 7 Service Parts ...

Page 8: ...se order must be issued Credit if any is issued only after return and evaluation is complete Dorner has representatives throughout the world Feel free to contact Dorner for the name of your local representative Our technical sales and service staff will gladly help with your questions on Dorner products For a copy of Dorner s Limited Warranty contact factory distributor service center or visit our...