14
English
This is only possible for the eSET Touchfree with temperature
setting.
If regular thermal disinfection is called for, the system can be
activated so that hot water runs from the fitting for 5 minutes.
Thermal disinfection requires hot water of at least 70 °C / 158 °F
to be available and the thermostat must be set to hot.
!
WARNING!
Danger of Scalding Due to Hot Liquids!
–
During thermal disinfection, the water that emerges can reach
a temperature of 70 °C / 158 °F or more.
–
Avoid any contact with the water jet and the water spray!
–
Any scalds should be examined by a physician and treated, if
necessary.
!
WARNING!
Danger of Burning Due to Hot Surfaces!
–
The very hot water flowing through the spout can heat it up.
–
Avoid touching the spout during thermal disinfection and for
5 minutes afterwards.
–
Any burns should be examined by a physician and treated, if
necessary.
!
WARNING!
Danger of Scalding Due to Hot Liquids!
–
The thermostat must be reset to the normal temperature
immediately after thermal disinfection!
– Any scalds should be examined by a physician and treated, if
necessary.
– Please refer to the water temperature settings on page 13 for
temperature adjustment.
CLEANING STOP
3 sec
Keep your finger on the “CLEANING STOP” dot of the Touchfree
box for longer than 10 seconds. You hear a beep. The system is
then in thermal disinfection mode. Hot water flows continuously.
Thermal disinfection ends automatically after 5 minutes.
CLEANING STOP
3 sec
If you keep your finger on the “CLEANING STOP” dot of the
Touchfree box for a further 3 seconds, this ends thermal disinfection.
You hear a beep. The thermostat must be reset to the normal
temperature immediately after thermal disinfection!
Please refer to the water temperature settings on page 13 for
temperature adjustment.
Thermal disinfection
Once a month, operate the thermostat at full flow over the
entire temperature range, to ensure perfect operation. Dornbracht
recommends to maintain the product professionally once a year.
Dornbracht recommends to conclude a maintenance contract to
ensure the periodic inspection.
Maintenance
Rated voltage
100 – 240 V AC
Input frequency
50 – 60 Hz
Output voltage
12 V DC
Rated power
5 W
Degree of protection
IP X4
Permissible Ambient Temperature
5 – 35 °C / 41 – 95 °F
Sensor frequency
5,785 – 5,815 MHz
Contains: FCC ID W8J-SIR13D, IC 8529A-SIR13D
Hereby, Aloys F. Dornbracht GmbH & Co. KG declares that the
radio equipment type eSET Touchfree is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of confor-
mity is available at the following internet address:
http://www.dornbracht.com/ce
Technical information