background image

INSTALLATION

R03-18GR-5

IS910TC

910TC

Touchless Switch

This touchless switch is ideal for areas where due to sanitary requirements a touchless switch is the only option. With a read range of 
1-2" inches (25-50mm) false triggering is limited.

Features:

• Fits on a single gang electrical box
• 12-24VDC
• Base Unit current draw  = 50mA resting, 115 mA activated
                  C/W Receiver  = 58mA resting, 122mA activiated
• Secondary mechanical switch on Normally Open Circuit - Max. 100mA
• Capacitive sensor activation
• Optional wireless transmitter and receiver available 
   as accessories

       © 2018 dormakaba Canada Inc.

        www.rutherfordcontrols.com • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • Email: [email protected]

1) Front plate removal: Apply pressure to the bottom of the front plate and pull the top of the plate away from the back plate.
2) Wire as per the chart on Page 2.
3) Set DIP switches ON for desired unlock time (1 to 63 seconds): Switch 1 = 1 second, 2 = 2 seconds, 3 = 4 seconds, 4 = 8 seconds, 
    5 = 16 seconds and 6 = 32 seconds. For example Switches 2 + 4 = 10 seconds total.
4) DIP switches 7 & 8 are used to fine-tune the operation of the unit.
    If the unit is not activating when you wave your hand, turn on Switch 7 (RC).
    If the button triggers without activating, it may be due to local interference. Turn on Switch 8 (FT). 
    Turning Switch 8 on may diminish read range.
5) Install on single gang box with 6-32 x 1” screws provided.
6) Reinstall front plate by positioning bottom catches in place, lift and apply pressure to the top.

Installation Instructions:

1-3/4”

(43.5mm)

1/2”

(12.0mm)

3-1/4”

(83.3mm)

2-15/16”

(74.0mm)

4-11/16”

(118.5mm)

Mounting Dimensions:

Dip Switch detail

Reviews: