dormakaba Universal Patch Fittings PT30
Installation Instructions
833002
07-2019
Universal Patch Fittings
6
Install wall plate
Install fittings
Install inserts
2.3.1
Secure wall plate to
fitting shown above.
•
Hand tighten using
5mm hex key.
Hex key size
5mm
2.4
Install fittings on glass
Fig. 3
Wall plate
2.3
Secure wall plate to fitting
Fig. 4
2.4.1 Insert glass grommet.
2.4.2 Place fittings onto
glass.
2.4.3 Hand tighten fittings
with included M6x27
flat head screws.
1/16”
[1.5]
1/16”
[1.5]
Glass
grommet
Wall
plate
Wall plate
fasteners (x2)
Hex key size
5mm
2.5.1 Place pivot
pin into
insert.
2.5.2 Secure with
set screw.
2.5.3 Place pivot
insert into
top of PT20.
Fittings
2.4.4 Temporarily
support transom
to mark wall
plate location.
2.4.5 Lift and secure transom to ceiling/
frame surface using product
appropriate to transom weight and
height.
2.4.6 Secure wall plate with
two included
fasteners.
2.4.7 Tighten
and
torque
fitting.
Torque value
Fittings
10 ft lbs
[15Nm]
2.5
Install inserts
Fig. 5
2-3/4” [70] from
wall/sidelight to
center of insert
PT30 Stop Insert
PT30 Blank Insert
2.5.1 Align stop insert.
•
Ensure white bumper is
facing operator.
2.5.2 Secure with included
fasteners.
2.5.1 Align blank insert.
•
Ensure fastener-side is
facing operator.
2.5.2 Secure with included
fasteners.
Stop
Blank
Pivot
PT20
Set
screw
PT30 Pivot Insert
Pivot
pin
Mark hole
location
Right hand door shown
Right hand door shown
White
bumper
Fastener-
side