Dormakaba MUTO Comfort Mounting Instructions Download Page 5

5

MUTO Comfort / Premium

2020-03

dormakaba Montageanleitung

Mounting instructions

Manual locking/unlocking (directly on the control unit)

WN 058855 45532

5.2  Procedure for wall switch BRC-W

Fig. 6 

Wall switch BRC-W

Carry out the following points (1 – 3) within 
20 seconds, otherwise the teach-in mode is 
automatically terminated

1. 

Briefly press the teach-in button on the 
transmitter. Do not press the transmitter’s touch 
surface.

 

‣ The transmitter’s device LED flashes green.

2. 

Press the transmitter’s touch surface.

 

‣ The device LED flashes orange.

3. 

Press the locking device’s teach-in button for 
more than 4 seconds.

 

‣ The locking device LED flashes red briefly; the 

transmitter LED flashes green for 3 seconds. 
The devices are connected.

 

‣ The device LED lights up red for 2 seconds; 

the transmitter LED lights up red for 
3 seconds. Teach-in has failed: reset 
programming and repeat teach-in.

4. 

Check locking device function with door in closed 
position.

To connect additional transmitters to the locking 
device, repeat steps 1 – 4.

Manual locking/unlocking (directly on 

the control unit)

The locking device can be operated manually 
independently of the hand-held transmitter or wall 
switch. If this is required, briefly press the teach-in 
button (see Chapter 3.4) once.

Reset programming

To reset the programming, delete the transmitter and 
receiver data (locking device).

Procedure for transmitter and receiver (locking 
device):

1. 

Press the teach-in button for more than 4 
seconds.

 

‣ The device LED flashes red slowly.

To cancel the reset, briefly press the teach-in button 
again. The slow red flashing stops.

2. 

Press the teach-in button for more than 4 seconds 
again.

 

‣ The device LED starts flashing red more 

rapidly.

 

‣ When you release the teach-in button, the 

device 

LED

•  flashes red briefly when it is locked,
•  flashes red for 3 seconds on the BRC-W or
•  the red LED goes out on the BRC-H.

 

The transmitter and receiver are reset.

Perform a function test

If an error has occurred, perform a function test.

1. 

If necessary remove the batteries and replace 
them with new batteries.

The radio transmitter’s function is restored (see the 
radio transmitter’s flashing codes).
If the device is not ready for use afterwards, this is 
due to the duty cycle being exceeded (see Chapter 3.6 
Flashing codes and Chapter 3.7 Warning thresholds). 
The control unit is unaffected by the duty cycle.

Maintenance and care

•  At least 2 years maintenance-free operation  

(at 10 operations per day)

•  Replace damaged components immediately 
•  Only use original dormakaba parts

Summary of Contents for MUTO Comfort

Page 1: ...nce manual for manual sliding doors 1 4 Documents storage This manual must be kept during the service life of the product and must be passed on with the product 2 Safety 2 1 Intended use Only use the locking device in indoor areas and prevent the effects of humidity dust and sun or other heat radiation Only load the locking device up to the specified power limit Overloading can lead to destruction...

Page 2: ... Premium XL 80 150 Parts included 3 2 Technical data Radio frequency 868 3 MHz Typ free field range 100 m Power supply 4x 1 5 volt lithium battery type AAA Battery life approx 2 years at 10 operations per day Standby power consumption 100 μA Dimensions WxHxD 14 x 18 8 x 64 mm Temperature 10 C to 55 C Humidity max 90 RH non condensing 3 3 Variants Fig 3 With battery pack 3 4 Locking device structur...

Page 3: ...beeping when DIP switch 2 OFF Audible warning active is set Warning threshold 1 2 beeps battery replacement is recommended Warning threshold 2 6 beeps battery replacement is required The locking device can only unlock and then becomes inoperative Removing the batteries resets the meter Therefore we recommend only removing the batteries to replace them Otherwise the meter will not reflect the true ...

Page 4: ...r insert tighten the cable ties and cut off the protruding end 18 Insert the batteries observing the polarity Optional cable set Art 36 855 for the locking device function as a status indicator Fig 4 green 3 yellow 4 grey 5 locked NO External status display max 30 V 1 A unlocked NC C Cable colors for the optional cable set 5 Connect locking device to a transmitter Please read this section complete...

Page 5: ...itter or wall switch If this is required briefly press the teach in button see Chapter 3 4 once 7 Reset programming To reset the programming delete the transmitter and receiver data locking device Procedure for transmitter and receiver locking device 1 Press the teach in button for more than 4 seconds The device LED flashes red slowly To cancel the reset briefly press the teach in button again The...

Page 6: ...e replaced by the operator Dismantling is carried out in reverse order of the mounting instructions Please refer to the mounting instructions for your MUTO sliding door system Proceed as follows to replace the battery 1 Remove the end caps Fig 7 1 and the cover profile Fig 7 2 from the track Fig 7 1 2 Remove the end cap and the cover profile 2 Replace the batteries observing the polarity Fig 8 Rep...

Page 7: ...ovisions of the listed EC Directive s and that the standards and or technical specifications referred to below have been applied Directive 2014 30 EU Electromagnetic Compatibility 2014 53 EU Radio Equipment 2011 65 EU RoHS The technical documentation is available from the Product Compliance Manager at product compliance dach dormakaba com Harmonized European standard national rule EN 300 220 1 V3 ...

Page 8: ...Translation of the original document subject to change without notice DORMA Glas GmbH Max Planck Straße 33 45 32107 Bad Salzuflen Germany T 49 2333 793 0 F 49 2333 793 4950 www dormakaba com ...

Reviews: