Not inputting anything for 10 seconds will cancel the authorization.
•
Virtual number function can be used in order not to expose your passwords. (However, the length
of password plus the virtual number cannot exceed 21 digits, or it will end up with an error sound)
•
Five attempts allowed before the authorization gets suspended for one minute. After that, you
may try again.
•
The guest password will go invalid after using it to open the door.
Open the door from outside with a RFID card
In auto detection mode
Put the RFID card on the reader
In manual detection mode
1.
2.
3.
Open the cover, or touch the
keypad
Press [*] button and close the
cover
Put the RFID card on the reader
或
或
•
In the double authorization mode, enter the password first
Lock door from outside
In auto lock mode
•
The door will automatically be locked in 2 seconds after it is closed.
In manual lock mode
•
Open the cover will lock the door after it is closed.
•
Open the cover and touch the keypad will lock the door after it is closed.
Lock door from inside
In auto mode
•
The door will automatically be locked in 2 seconds after it is closed.
In manual lock mode
•
Press [OPEN/CLOSE] button will lock the door after it is closed.
•
Turning “[Manual open/close]” to the “Close” position will lock the door.
Set internal double lock
.
Can prevent opening the door from outside
Set internal double lock
•
While the door is locked, press [OPEN/CLOSE] button for 3 seconds.
Release internal double lock
•
Press [OPEN/CLOSE] button or turning the [Manual open/close] to the “Open” position.
Set external double lock
.
This function disables the [OPEN/CLOSE] button
Set external double lock mode
1.
2.
3.
Open the cover or touch the
keypad
Press [*] button
Press [0] button
或
Release external double lock
Once the door is opened by the “[Manual open/close]” device, a password, or a RFID card, the
external double lock will be released.
Delete a password
Delete a password
1.
2.
3.
Enter the deletion mode
Press [1] button, and input an
address (1–4) to be deleted
Press [*] button
Delete all user passwords
1.
2.
3.
Enter the deletion mode
Press [1] button
Press [#] button for three
seconds
3 seconds
Delete a guest password
1.
2.
3.
Enter the deletion mode
Press [4] button
Press [*] button
Open the door from outside with a password
In General authorization mode
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator/user/
guest password
Press [#] button or close the
cover
or
or
•
A series of virtual numbers can be entered before or after step 2 while the virtual number
function is activated for opening the door.
In double authorization mode
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator/user/or
guest password
Press [#] button, close the cover,
and put an administrator/user
RFID on the reader
or
•
Setting a double authorization for guest passwords is not allowed.
•
A double authorization will not work for RFID card.
•
A series of virtual numbers can be entered before or after step 2 while the virtual number
function is activated for opening the door.
Delete a RFID card
Delete an administrator RFID card with an address
1.
2.
3.
Enter the deletion mode
Press [0] button, and
input the address to be deleted
(1–10)
Press [*] button
Delete an administrator RFID card
1.
2.
3.
Enter the deletion mode
Press [0] button
Put an administrator RFID card
on the reader
Delete all administrator RFID cards
1.
2.
3.
Enter the deletion mode
Press [0] button
Press [#] button for three
seconds
3 seconds
Delete a user RFID card with an address
1.
2.
3.
Enter the deletion mode
Press [2] button, and
enter the address to be deleted
(1–100)
Press [*] button
Delete a user RFID card
1.
2.
3.
Enter the deletion mode
Press [2] button
Put a user RFID card on the
reader
Delete all user RFID cards
1.
2.
3.
Enter the deletion mode
Press [2] button
Press [#] button for three
seconds
3 seconds
Open the door from inside
Normal mode
Press [OPEN/CLOSE] button will open the door if the door is locked.
Safety mode
Press [Safety mode] button and then press [OPEN/CLOSE] button will open the door.
Set double authorization
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator
password, and press
[*] button
Press [5] button: Set
Press [8] button: Clear
or
Set Clear
Set safety mode
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator
password, and press
[*] button two times
Press [5] button: Normal mode
Press [6] button: Safety mode
or
2 times
or
Normal Safety
mode mode
•
In normal mode: Press [OPEN/CLOSE] button will open the door.
•
In Safety mode: Press [Safety mode] button and then press [OPEN/CLOSE] button will open
the door.
Set auto/manual detection with RFID card
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator
password, and press
[*] button two times
Press [1] button: Auto detection
Press [3] button: Manual
detection
or
2 times
or
Auto Manual
detection detection
•
Auto detection mode is set by default.
•
In the manual detection mode, touching the keypad with a hand and put RFID card on the
reader will open the door.
Set auto/manual lock mode
Set Auto/manual lock
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator
password, and press
[*] button two times
Press [4] button: Auto lock
Press [7] button: Manual lock
or
2 times
or
Auto Manual
lock lock
In manual lock mode, choose to use the keypad cover to close the door
1.
2.
3.
Open the covrer, or touch the
keypad
Input an administrator
password, and press[*] button
two times
Press [8] button: Disabled
Press [9] button: Enabled
or
2 times
or
Disabled Enabled
•
Auto lock mode is set by default.
•
In auto lock mode, the door will automatically be locked in 2 seconds after it is closed.
•
In manual lock mode, the door will not be automatically locked after it is closed.
Volume control
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator
password, and press
[*] button
Press [3] button: Volume up
Press [6] button: Volume down
or
or
Volume Volume
up down
•
The volume can be adjusted by seven degrees.
Set doorbell
Set doorbell volume
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator
password, and press
[*] button
Press [1] button: Volume up
Press [4] button: Volume down
or
or
•
"For Elise" is set by default for the door bell.
•
Open the cover will stop the door bell.
Disable doorbell setup
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator
password, and press
[*] button
Press [7] button
or
•
· Doorbell is disabled by default.
•
· The doorbell will work only in the manual lock mode.
Interlock/Remote control
.
The Interlock/remoter will be sold separately
Register an interlock/remote control
1.
2.
3.
Enter the registration mode
Press [OPEN] button
Press [#] button
or
Interlock Remote
device control
•
Repeat step 2 before step 3 will register another interlock / remote control. (Up to five devices
may be registered)
Delete an interlock/remote control
1.
2.
3.
Enter the deletion mode
Press [5] button
Press [*] button
•
Registering a new device will automatically delete the one registered before.
Virtual number function
1.
2.
3.
Open the cover, or touch the
keypad
Enter an administrator
password, and press
[*] button two times
Press [0] button to activate
or not
or
2 times
•
Virtual number function is activated by default.
Alarm functions
Dead bolt trapping alarm
If the dead bolt is trapped when the door is opened or locked, alarm will go off and sounds like “beep
beep beep beep” for three times.
•
If the alarm never stops and the product does not function properly, contact an installation
engineer to adjust the product’s installation position.
Low battery alarm
Alarm will go off if it is under low battery and sounds like “beep beep beep” once the product turns
on.
•
When the battery alarm goes off, using the product without replacing the battery will fully
discharge the battery. Therefore, make sure to replace batteries when the alarm is on.
•
When replacing the batteries, replace them all with new ones.
•
Do not mix new batteries with partially discharged or fully discharged batteries.
•
Do not use batteries made from different manufacturers.
How to use an emergency battery
1. Connect an emergency battery (9 VP) to the emergency power supply terminals.
2. Input an administrator/user password, and press [#] button.
3. (In the double authorization mode) Put an administrator/user
4. RFID card on the reader.
· If the product does not work because of discharged battery, buy a new one (9 V).
Break-in / Damage alarm
80dB alarm will go off if anyone attempts to damage the lock or force the door to open.
•
If you remove the battery input a password or put the RFID card on the reader, the alarm will
stop.
Overheat warning
When a high temperature (62°C ± 5°C) is detected, alarm will go off and the lock mode will be
removed in case a fire broke out.
•
If the indoor unit is exposed to direct sunlight for a long period, alarm will go off as well.
•
If overheat is detected, internal double lock mode will be automatically removed.
•
This alarm won’t be off while the product is overheated.
Multiple entry failure alarm
Entering a nonregistered password or reading a nonregistered RFID card for five consecutive times
will make alarm go off and disable authorization for one minute.
•
Try to enter the right password or read the right RFID card after one minute to open the door.