background image

1  About this manual

1.1  Information about the 

manual

This instruction is part of the product. The instruction 
comprises important instructions for safe operation. 
Therefore, the instruction must be carefully read 
before using the product. This instruction must be 
kept during the service life of the product and must 
be passed on with the product. This instruction 
describes the installation, startup, maintenance and 
disassembly of the slide rail system GSR-EMR XEA. 
The text of the instruction is supported by figures in a 
separate figure part. The chapter numbers in the text 
can be found again top left in the figures in the figure 
part. There is not always a figure in the figure part to 
support a chapter in the text.

1.2  Target groups

The installation, startup, maintenance and 
disassembly must only be carried out by skilled staff 
which has been authorized by dormakaba. The 
acceptance test must only be carried out by skilled 
staff that is certified for this by dormakaba. The 
operation of the slide rail system may be carried out 
by any person who is mentally and physically able.

1.3  Provided documents

•  Installation manual
•  Connection diagrams RMZ/RM-ED
•  Data sheet about the use of arrest systems
•  General building approval

1.4  Symbols and abbreviations 

used

1.4.1  Safety instructions

DANGER

This signal word indicates a situation of 
immediate risk, which will lead to death or 
serious injury if not averted.

CAUTION

This signal word indicates a situation of 
potential risk, which could lead to minor or 
slight injury if not averted.

ATTENTION

This signal word indicates a situation of 
potential risk, which could lead to damage 
to property or the environment if not 
averted.

TIPS AND RECOMMENDATIONS

This signal word indicates useful information 
for efficient and trouble-free operation.

1.4.2  Further labeling

2.

1.

Step-by-step graphics

1

2

Position numbers of parts

The illustration shows the mounting 
DIN-L on the hinge side.

Illustration shows mounting DIN-L on 
the opposite hinge side.

The illustration shows the mounting 
DIN-R on the hinge side.

Illustration shows mounting DIN-R on 
the opposite hinge side.

1.4.3  Tool symbols

Allen wrench, e.g. wrench size 3

1.5  Glossary

EMF   Electromechanical locking device 
HT 

Manual release button

RMZ   Smoke detection panel
RS 

Smoke switch

TS  

Door closer

2

G-EMR XEA

2018-11

dormakaba

WN 059420 45532

About this manual

Installation manual

Summary of Contents for G-EMR XEA

Page 1: ...3 3 Product description 4 3 1 RMZ 4 3 1 1 DIP switch on the RMZ 4 3 1 2 Clamp terminal assignment of the RMZ 4 3 1 3 Display of the operating status of the RMZ 4 3 2 EMF 4 3 3 Technical data 4 3 3 1 RMZ 4 3 3 2 EMF 4 4 Installation 5 4 1 Prepare the mounting of the slide rail 5 4 2 Mount the base 5 4 3 Mount the slide rail and RMZ 5 4 4 Mount the door closer 5 4 5 Establish electrical connections ...

Page 2: ...rovided documents Installation manual Connection diagrams RMZ RM ED Data sheet about the use of arrest systems General building approval 1 4 Symbols and abbreviations used 1 4 1 Safety instructions DANGER This signal word indicates a situation of immediate risk which will lead to death or serious injury if not averted CAUTION This signal word indicates a situation of potential risk which could lea...

Page 3: ... circuit breaker simultaneously serves as disconnect device to switch the RMZ to zero potential The transverse section of the mains supply line must only be a max 3 x 1 5 mm NYM 2 Safety DANGER Danger to life through electric current Works on electrical systems must only be carried out by skilled electricians Before starting work on electrical systems and equipment establish a zero potential condi...

Page 4: ...l manual release with terminating resistor 43 kOhm 10 7 NO Potential free changer low voltage SELV 24 V AC DC 1 A 8 NC 9 C 11 Potential free clamp 16 Bus 3 1 3 Display of the operating status of the RMZ Functions of the LEDs LED on LED off Operating display LED 1 green red operation green Alarm smoke detector red Alarm manual release button red Service display LED 2 yellow Maintenance due flashing...

Page 5: ...base 7 Screw the slide rail onto the base 8 Insert the connection cables of the EMF into the RMZ 4 4 Mount the door closer 1 Mount the door closer and lever to the door closer according to the enclosed instructions for the door leaf 2 Adjust the door closer 4 5 Establish electrical connections 1 Connect the 230 V AC connection cable For maintaining the protection category II protective insulation ...

Page 6: ...can be released manually or by cutting of the power supply 5 6 1 Release EMF manually 1 Open the door leaf and lock it 2 Pull on the door leaf The door leaf is released and closes 5 6 2 Delete EMF electronically 1 Open the door leaf and lock it 2 Cut off the power supply i e operation of the manual release button The door leaf is released and closes 5 7 Check the function of the catching device vi...

Page 7: ...est After installation an acceptance test is to be carried out according to the test book for catching devices The acceptance test must only be carried out by skilled staff that is certified for this by dormakaba Follow the details from the data sheet about the use of catching devices The acceptance test must be documented in the test book for catching devices 7 Operating 7 1 Open and lock door 1 ...

Page 8: ...dormakaba Deutschland GmbH DORMA Platz 1 58256 Ennepetal Germany T 49 2333 793 0 F 49 2333 793 4950 www dormakaba com 013558 Translation of the original manual subject to change without notice ...

Reviews: