About this quick guide

Validity

This quick guide describes the product:

Product designation

dormakaba registration unit 90 01

Product ID

9001-K6

Item number

04079003

Date of manufacture

From February 2020

Target group

This quick guide should only be used by skilled persons trained by
the manufacturer.

Supplementary documentation

The registration unit operates as a peripheral component to a par-
ent control unit. The essential system functions can therefore be
found in the technical manual for the parent unit.

Additional documentation is available on the Internet at the
dormakaba website. The technical manuals are located in a protec-
ted area. They can be accessed via the user account of trained pro-
fessionals. However, you can also create a temporary account.

https://www.dormakaba.com/extranet-emea-en

Safety instructions

Designated use

This product is intended for use as specified and explained in the
Product description section only. Any other use is considered non-
designated use. The manufacturer is not liable for any damage or
injury due to non-designated use. The user/facility operator is the
sole person to bear risks for non-designated use.

Staff qualification

The actions described in this quick start guide must only be carried
out by skilled persons in accordance with EN 62368-1.

Skilled person is the designation for people who have the appropri-
ate technical training and experience in setting up the equipment.
Skilled persons are expected to use their training and experience to
identify any risks to themselves and others that may arise while
carrying out these activities, and to minimise these risks as far as
possible. It is the skilled person’s responsibility to ensure that the
conditions stated by the manufacturer and the applicable regula-
tions and standards are complied with when carrying out these ac-
tions.

Assembly and installation

The product should only be installed in locations which fulfil the en-
vironmental and technical conditions specified by the manufac-
turer.

The manufacturer is not liable for damage arising due to improper
handling or incorrect installation.

Environmental protection

Do not dispose of the product in your domestic waste, but have it
recycled.

ESD protective measures

NOTICE

Danger for electronic components due to electrostatic discharge.

Improper handling of printed circuit boards and components may
cause damage leading to complete failure or malfunction of the
device.

Applicable ESD protective measures must be observed and ap-
plied when using electronic components.

Product description

The registration unit is a remote reader for authorization checking
within an access control system.

The registration unit enables the contactless reading and writing of
RFID media as well as access via a smartphone (Mobile Access).

The registration unit supports the following technologies:

RFID MIFARE DESFire/Classic

RFID LEGIC advant/prime

NFC (Android Smartphone)

Bluetooth Low Energy (Android Smar iPhone)

The actually usable technologies depend on the system solution in
which the registration unit is integrated.

The registration unit is connected to a superior control device using
a coaxial cable.

The registration unit is installed directly on the wall in the door
area.

The registration unit is equipped with a light icon (red/green) and a
buzzer for optical and acoustic signalling.

Product versions

The product is available for the following installation variants:

back housing (19,4 mm) for flush cable mounting

back housing with spacer frame (26,4 mm) for surface cable
mounting

The product is available in the following color variants:

Black/white aluminum (RAL9005/9006)

White/white aluminum (RAL9016/9006)

Summary of Contents for 90 01

Page 1: ...hat the conditions stated by the manufacturer and the applicable regula tions and standards are complied with when carrying out these ac tions Assembly and installation The product should only be installed in locations which fulfil the en vironmental and technical conditions specified by the manufac turer The manufacturer is not liable for damage arising due to improper handling or incorrect insta...

Page 2: ...e used The product is designed for the stationary use in buildings The product is not suitable for the use in vehicles Distances RFID fields which are close together can influence one another thereby reducing the reading and writing distances A distance of 20 cm must be maintained on all sides between two registration units which are not in operation on the same control unit In Mobile Access syste...

Page 3: ...ctor of coaxial cable Switch settings On the back of the front panel there is a switch bank for setting the received signal strength RSSI value This switch bank can be used to set or limit the range of Mobile Ac cess via Bluetooth Low Energy BLE 1 2 3 4 RSSI dBm OFF OFF OFF OFF BLE OFF ON OFF OFF OFF 30 OFF ON OFF OFF 32 ON ON OFF OFF 34 OFF OFF ON OFF 35 ON OFF ON OFF 36 OFF ON ON OFF 37 ON ON ON...

Page 4: ...r level control system The following descriptions refer to default settings Signaling The operator is guided by optical and acoustic signals Signaling Meaning green permanent in attendance red permanent access blocked green short acoustic signal access authorised red flashing short acoustic signals access not authorised Booking with RFID media The contactless media are held in front of the input f...

Reviews: