END COVERS
8
adjusted to meet barrier-free forces may not have sufficient
Take an opening force reading from
CAUTION: DO NOT OVERTIGHTEN
to meet the barrier-free requirement. Maximum number of
clockwise =12. Depending on opening conditions, a door
turns counter clockwise=5. Maximum number of turns
power to reliably close and latch the door.
ULC LABELED UNITS "ONLY"
NON-BARRIER-FREE OPENINGS:
Adjust according to chart.
Adjust according to chart.
Adjust spring tension, if required.
TS93-1 supplied with a size 2 spring setting.
CRITICAL
the pull on the door. If required, adjust the spring tension
REFERENCE LABEL ON CLOSER FOR MINIMUM/MAXIMUM SETTINGS
BARRIER-FREE OPENINGS -
+
-
+12
200
5
WEIGHT (LBS)
CLOSER
TS93-1
TYPE
100
150
125
DOOR
4'
3'6"
3'
2'6"
3'6"
MAX.
3'
2'6"
---
SPRING
ADJUSTER
OF SPRING
2
4
3
SIZE
0
+9
+3
FULL TURNS
+12
+3
+9
0
5
3
4
2
SPRING ADJUSTER
FULL TURNS OF
INT.
DOOR WIDTH
EXT.
CLOSER
SIZE
M5 HEX KEY
NOTE:
TS93-5 supplied with a size 6 spring setting.
NOTE:
Maximum number of turns clockwise = 6
TS93-1
0
SPRING ADJUSTER
FULL TURNS OF
4'
4' 6"
TS93-5
DOOR WIDTH
EXT.
3' 6"
INT.
4'
-4
6
CLOSER
SIZE
5
0
-4
5
6
200
250
TS93-5
08280611
3 of 3
08/09
INS NO.
PAGE
Rev.
screw.
Secure with locking
TAB
COVER
cover onto plate.
end caps.
Slide end covers over closer body
REMOVE
Remove tab that aligns with arm hub. Slide
Install cover.
9