Prosecure Opti Motion Stereo
—
5
DORMA
Secured access
The sensor can be protected with a code to prevent against
unauthorised programming.
Activating access protection using a code
1.
Select the "Code" parameter and confirm with
ü
.
2.
Select "Access with code" and confirm with
ü
.
3.
Enter 4-digit code.
4.
Repeat code.
• The sensor is now protected.
Deactivating access protection using a code
1.
Establish a connection with the sensor.
2.
Select the "Code" parameter and confirm with
ü
.
3.
Select "Access without code" and confirm with
ü
.
• Access protection is now deactivated.
Disable access
1.
Select the "Code" parameter and confirm with
ü
.
2.
Select "Disable access" and confirm with
ü
.
• Access with the remote control is now no longer
possible.
Establishing a connection with the sensor
1.
Select the sensor type and confirm with
ü
.
2.
Select or search for an address
and confirm with
ü
.
3.
If the sensor is protected, enter the 4-digit code
and confirm with
ü
.
• The sensor can now be programmed.
Programming the sensor
1.
Select the parameters and confirm with
ü
.
2.
Read the setting and confirm with
ü
.
• The current setting is displayed.
3.
Adjust the required setting and confirm with
ü
.
4.
Return to parameter list with
.
5.
Proceed in the same way with other parameters.
Remote control settings
(check the setting by walking the detection area)
Menu
Settings
Description
Sensitivity
1 - 16
1: Small detection area
16: Large detection area
Detection mode
Off
Stereo forward
Stereo backward
Mono
No detection
Detects movements in the direction of the sensor
Detects movements away from the sensor
Detects both forward and backward movements
Off-delay time
(output)
Off
0.2 s, 0.5 s, 1 s,
1.5 s, 2 s, 3 s, 4 s, 5 s
Off: Relay is not operating
0.2 s: Shortest off-delay time
5.0 s: Longest off-delay time
Relay contact
NO contact
NC contact
Relay contact closes on detection (NO)
Relay contact opens on detection (NC)
Cross-traffic
suppression
Off
1 - 10
Off: No cross-traffic optimization
0
1: Low cross-traffic optimization
10: High cross-traffic optimization
Slow Motion
Door open
(LED red)
Off
1 s, 3 s, 5 s
1*
Off: Slow motion deactivated
Monitoring time/sensitivity
Slow Motion
Door closed
(LED green)
Off
On
Slow motion deactivated
Slow motion activated
Slow motion field
Door open.
1 - 10
0
1: Small detection area
10: Large detection area
Slow motion field
Door closed
1 - 10
0
1: Small detection area
10: Large detection area
Immunity
1 - 7
1: Minimum immunity
7: Maximum immunity
Standard profiles Profile 1 - 16
For settings see "DIP switch settings" table
Reset
Reset to original settings
Code
Access with code
Disable access
Access without code
Access with remote control is only possible after
a code is entered.
Access is disabled. No remote control access
possible.
Access with remote control is possible at all times.
Disconnect
Exit programming mode
Setting the Address
Sensor
address
DIP switches
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1*
- The sensor turns off the detection if no movement within the set time.