(1)

QTY

SNAP VALVE ADJUSTMENT
WRENCH INSIDE COVER

08279401

3 of 3

09/09

INS NO.

PAGE

Rev.

Adjust according to chart.

ADJUSTER

FULL TURNS

OF SPRING

0

+4

+12

FULL TURNS

OF SPRING

ADJUSTING NUT

ADJUST SPRING TENSION ACCORDING TO THE FOLLOWING CHART.

8916

8956

CLOSER

ULC LABELED UNITS ONLY

TYPE

200

200

6

5
6

0

SIZE

SPRING

DOOR

WEIGHT

150

100
125

MAX.

3
4

-12

NON-BARRIER-FREE OPENINGS -

3'-6"

3'-6"

3'-0"

2'-6"

EXTERIOR

TYPE

8916

8956

CLOSER

INTERIOR

2'-6"

4'-0"

3'-6"

3'-0"

4'-0"

-

+4

0

+12

-12

0

DOOR WIDTH

5

6

6

3
4

SPRING

SIZE

Take an opening force reading from

the pull on the door.  If required, adjust the spring tension

to meet the barrier-free requirement. Maximum number of

adjusted to meet barrier-free forces may not have sufficient
power to reliably close and latch the door.

turns counter clockwise=8. Maximum number of turns
clockwise =14.  Depending on opening conditions, a door

BARRIER-FREE OPENINGS -

8916 ONLY

ADJUSTER

Adjust spring tension, if required, using a 1/4" wrench.

8956 supplied with size 6 setting.

8916 supplied with size 4 spring setting. 

SPRING TENSION

CRITICAL

NOTE:

+

-

5

-6

3'-6"

3'-0"

-6

5

150

-

4'-0"

+6

6+

+6

6+

250

5

6

7

C

L  HINGE

NOTE: LEFT HAND DOOR
INSTALLATION SHOWN.
RIGHT HAND IS A MIRROR IMAGE.

6mm HEX KEY

45°

PINION

ROTATE

PINION SCREW

PINION

main arm onto top pinion. Fasten securely  

STEP #4 CONTINUED...

With connecting arm parallel to door, place  

with pinion screw.

CONNECTING ARM

BACKCHECK OR DELAYED ACTION

NOTE: DELAYED ACTION IS AN OPTIONAL FEATURE.

DECREASE

control when extra time is required to pass through

Optional delayed action offers additional closing speed

the door. All valve adjustments are made with a 3/32"

CAUTION: DO NOT REMOVE VALVES.

DELAYED ACTION

BACKCHECK RANGE

SWEEP (SPEED)

INCREASE

(SPEED)

LATCH

RANGE

(TIME)

ACTION

DELAYED

hex key.

SWEEP & LATCH

POSITIONING VALVE

BACKCHECK (INTENSITY)

RANGE

LATCH

SWEEP

RANGE

DECREASE

INCREASE

should take a minimum of 1.5 seconds.

Closing time from 15° to fully closed (latch range)

generally adjusted to take a minimum of 3 seconds.

Closing time from 90° to 15° (sweep range) is

Adjust sweep and latch valves.

Place tab in cover slot opposite main arm.
Place cover over closer and fasten securely with
screws provided.

HAND IS A MIRROR IMAGE.

QTY

TAB

(2)

NOTE: LEFT HAND INSTALLATION SHOWN. RIGHT