![D'Orly DO5500E Owner'S Manual Download Page 18](http://html1.mh-extra.com/html/dorly/do5500e/do5500e_owners-manual_3071447018.webp)
18
Do not close the choke when starting the engine in a warm state.
2.
Electronic starter
Turn the generator switch to the electric starting position and hold for
a maximum of 5 seconds or less if the engine is started. If starting fails,
release the switch and wait for 10 seconds before using it again.
If the speed of the starting motor drops fast after holding the switch for
some time, it means the battery should be recharged.
NOTICE
1.
Recoil starter
1) Remove all the loads from the output side.
2) Turn the fuel valve to the “=ON” position.
3) Turn the AC circuit breaker to the “OFF” position.
4) Turn the choke lever to the “CLOSE” position.
5) Turn the generator switch to the “ON” position.
6) Pull the starter grip until a resistance is felt, the pull it out briskly.
7) Turn the choke lever to the “OPEN” position after the engine is
warm.
8) Do not use electric devices before setting the circuit breaker to the
“ON”position.
6. STARTING THE ENGINE