Model
SS-2100
INSTRUCTIONS
SETUP AND ADJUSTMENTS
To adjust sensor height, hold straight edge across
pads (B1 & B2). Turn sensors (A & A) till distance
to straight edge equals the desired water detection
level. See Figure 2.
Connect the 3 Water Alert pigtail leads to the 3
conductor cable connecting to the terminal strips of
the Monitor. (Run cable thru 1/4" hole in Water Alert
housing.) The green pigtail (signal) goes to terminal
"G", of the Monitor, the black pigtail (common) goes
to terminal "B", and the red pigtail (power) goes to
terminal "R".
IMPORTANT: When connecting leads with wire nuts,
twist the leads together, then screw on wire nuts for
a tight mechanical connection. Tuck leads neatly
into the unit.
1.
2.
3.
4.
5.
6.
7.
FIGURE 2
BOTTOM VIEW
Test unit by touching wet fingers to both sensors.
The buzzer should sound, and remote monitor should
activate.
Position unit in desired location and retest it by placing
wet fingers across the heads of two screws on which
the sensors are mounted.
When activated, the unit will produce a signal that is
on for 2-3 seconds and off for 10-15 seconds.
To stop the signal shake the entire unit to break the
water bridge between the sensors. Dry off the sen
-
sors if they are excessively wet.
CAUTION
Not For Explosive Environments!